SYS
Word
Bit
Description
SYS21
Status of Profile Execution
B00
= 0 Normal
= 1 First Clamp Close Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
Module does not leave this bit set when holding outputs to FCC33 - 40 at completion of the First Clamp Close profile.
B01
= 0 Normal
= 1 Second Clamp Close Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
Module does not leave this bit set when holding outputs to SCC33 - 40 at completion of Second Clamp Close profile.
B02
= 0 Normal
= 1 Third Clamp Close Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
Module does not leave this bit set when holding outputs to TCC33 - 40 at completion of the Third Clamp Close profile.
B03
= 0 Normal
= 1 Low Pressure Close (LPC) Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
Mdule does not leave this bit set when holding outputs to LPC33 - 40 at completion of Clamp LPC profile.
B04
= 0 Normal
= 1 Injection Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
B05
= 0 Normal
= 1 Pack Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
B06
= 0 Normal
= 1 Hold Profile in Progress
The module sets this bit when it starts the profile.
The module resets this bit when:
S
it completes the profile, or
S
it receives a new action execution command that terminates the profile
The module does not leave this bit set when holding outputs to HDC33 - 40 at completion of the hold profile.
B07
= 0 Normal
= 1 Pre-decompression Movement in Progress
The module sets this bit when it starts the movement.
The module resets this bit when:
S
it completes the movement, or
S
it receives a new action execution command that terminates the movement
Module does not leave this bit set when holding outputs to PRC33 - 40 at completion of Pre-decompression movement.