Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 132

2–66
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
LPC09
Output #1 Set-output Value during Profile [19]
LPC10
Output #2 Set-output Value during Profile [19]
LPC11
Output #3 Set-output Value during Profile [19]
LPC12
Output #4 Set-output Value during Profile [19]
LPC13
Output #5 Set-output Value during Profile [19]
LPC14
Output #6 Set-output Value during Profile [19]
LPC15
Output #7 Set-output Value during Profile [19]
LPC16
Output #8 Set-output Value during Profile [19]
Output Ramp Rates
The module uses the following ramp rates when moving its outputs
from setpoint to setpoint during the Clamp Low Pressure Close
Profile. The module interprets a ramp rate entry of zero as a step
function ramp (ramp disable).
Word
Description
LPC17
Output #1 Acceleration Ramp Rate during Profile [20]
LPC18
Output #2 Acceleration Ramp Rate during Profile [20]
LPC19
Output #3 Acceleration Ramp Rate during Profile [20]
LPC20
Output #4 Acceleration Ramp Rate during Profile [20]
LPC21
Output #5 Acceleration Ramp Rate during Profile [20]
LPC22
Output #6 Acceleration Ramp Rate during Profile [20]
LPC23
Output #7 Acceleration Ramp Rate during Profile [20]
LPC24
Output #8 Acceleration Ramp Rate during Profile [20]
LPC25
Output #1 Deceleration Ramp Rate during Profile [20]
LPC26
Output #2 Deceleration Ramp Rate during Profile [20]
LPC27
Output #3 Deceleration Ramp Rate during Profile [20]
LPC28
Output #4 Deceleration Ramp Rate during Profile [20]
LPC29
Output #5 Deceleration Ramp Rate during Profile [20]
LPC30
Output #6 Deceleration Ramp Rate during Profile [20]
LPC31
Output #7 Deceleration Ramp Rate during Profile [20]
LPC32
Output #8 Deceleration Ramp Rate during Profile [20]
End of Profile Set-output Values
When the module completes the Clamp Low Pressure Close Profile, it:
•
sets its outputs to the following values
•
sets status bit SYS22-B03
•
uses ramp rates LPC17 - 32 when changing outputs to these values
Use these values to apply tonnage to the mold before starting the
Injection Profile, or for setting cores if applied before starting the
Injection Profile.