Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 247
4–23
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 9
0461
Your non-zero entry for IPC61 is out of range.
if:
then:
MCC13 and MCC14
IPC61 must be within 00000
≤
IPC61
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC61 must be within 00000
≤
IPC61
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC61 must be within 00000
≤
IPC61
≤
MCC14 – MCC09
MCC14 is non-zero .
MCC13 and MCC14
IPC61 must be within 00000
≤
IPC61
≤
MCC10 – MCC09
are both zero
0462
IPC62 is out of range.
If non-zero, IPC62 must be within MCC17
≤
IPC62
≤
MCC18
0463
IPC63 is out of range.
If non-zero, IPC63 must be within MCC57
≤
IPC63
≤
MCC58
0464
IPC64 is out of range.
if:
then:
MCC13 and MCC14
IPC64 must be within 00000
≤
IPC64
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC64 must be within 00000
≤
IPC64
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC64 must be within 00000
≤
IPC64
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC64 must be within 00000
≤
IPC64
≤
MCC10 – MCC09
are both zero
0503
You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1; however, your bit patterns in MCC02 and MCC03 indi-
cate that the QDC module does not have access to a connected ram (screw) pressure
transducer.
0504
You have selected closed-loop Press/Pos execution for the Injection Profile by IPC04-B02 =
0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does not
have access to a connected ram (screw) pressure transducer.
0508
You have selected closed-loop Press/Time execution for the Injection Profile by IPC04-B03
= 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC module does
not have access to a connected ram (screw) pressure transducer.
0600
Your entire Injection Profile Command Block has been rejected because the QDC module
does not have a valid Injection Configuration Command Block on-board (SYS15-B07 = 0).
0711
IPC11 cannot be 00000 because it conflicts with one of:
IPC13 > 00000 when IPC03-B01 = 0
C 3
00000
C03 0
0
IPC14 > 00000 when IPC03-B01 = 1
0712
IPC12 cannot be 00000 when IPC14 > 00000.
0715
IPC15 cannot be 00000 because it conflicts with one of:
IPC17 > 00000 when IPC03-B01 = 0
IPC18 > 00000 when IPC03-B01 = 1
0716
IPC16 cannot be 00000 when IPC18 > 00000.
0719
IPC19 cannot be 00000 because it conflicts with one of:
IPC21 > 00000 when IPC03-B01 = 0
C
00000
C03 0
0
IPC22 > 00000 when IPC03-B01 = 1
0720
IPC20 cannot be 00000 when IPC22 > 00000.
0723
IPC23 cannot be 00000 because it conflicts with one of:
IPC25 > 00000 when IPC03-B01 = 0
C 5
00000
C03 0
0
IPC26 > 00000 when IPC03-B01 = 1
0724
IPC24 cannot be 00000 when IPC26 > 00000.