Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 240
4–16
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 7
0503
Your selection to bridge the First Clamp Close Profile directly into the Second Clamp Close
Profile, and set-output upon conclusion of the Second Clamp Close Profile (CPC03-B08 = 0
and CPC03-B09 = 1) is invalid because the QDC module does not have a valid SCC on-board
(SYS15-B03 = 0).
0507
Your selection to bridge the first two Clamp Close Profiles directly into the Third Clamp Close
Profile, and set-output upon conclusion of the Third Clamp Close Profile (CPC03-B08 = 0,
CPC03-B09 = 0, and CPC03-B10 = 1) is invalid because the QDC module does not have a
valid TCC on-board (SYS15-B04 = 0).
0508
You have selected closed-loop Press/Pos execution for the Second Clamp Close Profile by
CPC04-B03 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0511
Your selection to bridge the Second Clamp Close Profile directly into the Third Clamp Close
Profile, and set-output upon conclusion of the Third Clamp Close Profile (CPC03-B09 = 0, and
CPC03-B10 = 1) is invalid because the QDC module does not have a valid TCC on-board
(SYS15-B04 = 0).
0512
You have selected closed-loop Press/Pos execution for the Third Clamp Close Profile by
CPC04-B05 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0516
You have selected closed-loop Press/Pos execution for the Clamp Low Pressure Close Profile
by CPC04-B07 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected clamp pressure transducer.
0600
Your entire Clamp Close Profile Command Block has been rejected because the QDC module
does not have a valid Clamp Low Pressure Close Configuration Command Block on-board
(SYS15-B05 = 0).
0609
Your CPC09 must be zero because of invalid FCC. (SYS15-B02 = 0).
0610
Your CPC10 must be zero because of invalid FCC. (SYS15-B02 = 0).
0611
Your CPC11 must be zero because of invalid FCC. (SYS15-B02 = 0).
0612
Your CPC12 must be zero because of invalid FCC. (SYS15-B02 = 0).
0613
Your CPC13 must be zero because of invalid FCC. (SYS15-B02 = 0).
0614
Your CPC14 must be zero because of invalid FCC. (SYS15-B02 = 0).
0615
Your CPC15 must be zero because of invalid FCC. (SYS15-B02 = 0).
0616
Your CPC16 must be zero because of invalid FCC. (SYS15-B02 = 0).
0617
Your CPC17 must be zero because of invalid FCC. (SYS15-B02 = 0).
0618
Your CPC18 must be zero because of invalid SCC. (SYS15-B03 = 0).
0619
Your CPC19 must be zero because of invalid SCC. (SYS15-B03 = 0).
0620
Your CPC20 must be zero because of invalid SCC. (SYS15-B03 = 0).
0621
Your CPC21 must be zero because of invalid SCC. (SYS15-B03 = 0).
0622
Your CPC22 must be zero because of invalid SCC. (SYS15-B03 = 0).
0623
Your CPC23 must be zero because of invalid SCC. (SYS15-B03 = 0).
0624
Your CPC24 must be zero because of invalid SCC. (SYS15-B03 = 0).
0625
Your CPC25 must be zero because of invalid SCC. (SYS15-B03 = 0).
0626
Your CPC26 must be zero because of invalid SCC. (SYS15-B03 = 0).
0627
Your CPC27 must be zero because of invalid TCC. (SYS15-B04 = 0).
0628
Your CPC28 must be zero because of invalid TCC. (SYS15-B04 = 0).
0629
Your CPC29 must be zero because of invalid TCC. (SYS15-B04 = 0).
0630
Your CPC30 must be zero because of invalid TCC. (SYS15-B04 = 0).
0631
Your CPC31 must be zero because of invalid TCC. (SYS15-B04 = 0).
0632
Your CPC32 must be zero because of invalid TCC. (SYS15-B04 = 0).
0633
Your CPC33 must be zero because of invalid TCC. (SYS15-B04 = 0).
0634
Your CPC34 must be zero because of invalid TCC. (SYS15-B04 = 0).
0635
Your CPC35 must be zero because of invalid TCC. (SYS15-B04 = 0).
0812
CPC12 must be 00000 when CPC11 = 00000.