1–11
Abbreviated Command and Status Blocks
Publication 1771-6.5.88 – July 1997
End of Profile Set-output Values
FOC33
N43:329
Output #1
FOC34
N43:330
Output #2
FOC35
N43:331
Output #3
FOC36
N43:332
Output #4
FOC37
N43:333
Output #5
FOC38
N43:334
Output #6
FOC39
N43:335
Output #7
FOC40
N43:336
Output #8
Pressure Control Limits
FOC41
N43:337
Minimum limit
FOC42
N43:338
Maximum limit
FOC43
N43:339
% output for minimum
FOC44
N43:340
% output for maximum
Velocity Control Limits
FOC45
N43:341
Minimum limit
FOC46
N43:342
Maximum limit
FOC47
N43:343
Minimum output for selected velocity valve
FOC48
N43:344
Maximum output for selected velocity valve
Profile Tuning Constants
FOC49
N43:345
Proportional gain, pressure control
FOC50
N43:346
Integral gain, pressure control
FOC51
N43:347
Derivative gain, pressure control
FOC52
N43:348
Proportional gain, velocity control
FOC53
N43:349
Feedforward gain, velocity control
FOC54-56
N43:350-352
RFU
Setpoints for Profile Pressure Alarm
FOC57
N43:353
High pressure alarm
FOC58-64
N43:354-360
RFU
Word
Pro-Set Address
Description
Bit-mapped Control Words
HDC01
B38:12
Block ID 00000000 00001011
HDC02
B38:13
Selected valve configurations
HDC03-04
B38:14-15
RFU
Expert Response Compensation Percentage
HDC05
N44:181
ERC % minimum cavity pressure
HDC06
N44:182
ERC % minimum ram pressure
HDC07-08
N44:183-184
RFU
Set-output Values for Unselected Valves (During Profile)
HDC09
N44:185
Output #1
HDC10
N44:186
Output #2
HDC11
N44:187
Output #3
HDC12
N44:188
Output #4
HDC13
N44:189
Output #5
HDC14
N44:190
Output #6
HDC15
N44:191
Output #7
HDC16
N44:192
Output #8
HDC – Hold
Configuration Block