4–48
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 21
MCC27 is zero and
OPC62 must be within OPC61 < OPC62
≤
MCC28 – MCC23.
MCC28 is non-zero
MCC27 and MCC28
OPC62 must be within OPC61 < OPC62
≤
MCC24 – MCC23
are both zero
0503
Your selection to bridge the First Clamp Open Profile directly into Second Clamp Open Profile,
and set-output upon conclusion of Second Clamp Open Profile (OPC03-B08 = 0 and
OPC03-B09 = 1) is invalid because QDC module does not have a valid SOC (SYS16-B01 = 0).
0504
You have selected closed-loop Press/Pos execution for the First Clamp Open Profile by
OPC04-B01 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.
0507
Your selection to bridge the first two Clamp Open Profiles directly into the Third Clamp Open
Profile, and set-output upon conclusion of the Third Clamp Open Profile (OPC03-B08 = 0,
OPC03-B09 = 0, and OPC03-B10 = 1) is invalid because the QDC module does not have a valid
TOC on-board (SYS16-B02 = 0).
0508
You have selected closed-loop Press/Pos execution for the Second Clamp Open Profile by
OPC04-B03 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.
0511
Your selection to bridge the Second Clamp Open Profile directly into the Third Clamp Open
Profile, and set-output upon conclusion of the Third Clamp Open Profile (OPC03-B09 = 0, and
OPC03-B10 = 1) is invalid because the QDC module does not have a valid TOC on-board
(SYS16-B02 = 0).
0512
You have selected closed-loop Press/Pos execution for the Third Clamp Open Profile by
OPC04-B05 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.
0516
You have selected closed-loop Press/Pos execution for the Clamp Open Slow Profile by
OPC04-B07 = 0; however, your bit patterns in MCC02 and MCC03 indicate that the QDC mod-
ule does not have access to a connected clamp pressure transducer.
0600
Your entire Clamp Open Profile Command Block has been rejected because the QDC module
does not have a valid Clamp Open Slow Configuration Block on-board (SYS16-B03 = 0).
0609
Your OPC09 must be zero because FOC is invalid (SYS16-B00 = 0).
0610
Your OPC10 must be zero because FOC is invalid (SYS16-B00 = 0).
0611
Your OPC11 must be zero because FOC is invalid (SYS16-B00 = 0).
0612
Your OPC12 must be zero because FOC is invalid (SYS16-B00 = 0).
0613
Your OPC13 must be zero because FOC is invalid (SYS16-B00 = 0).
0614
Your OPC14 must be zero because FOC is invalid (SYS16-B00 = 0).
0615
Your OPC15 must be zero because FOC is invalid (SYS16-B00 = 0).
0616
Your OPC16 must be zero because FOC is invalid (SYS16-B00 = 0).
0617
Your OPC17 must be zero because FOC is invalid (SYS16-B00 = 0).
0618
Your OPC18 must be zero because SOC is invalid (SYS16-B01 = 0).
0619
Your OPC19 must be zero because SOC is invalid (SYS16-B01 = 0).
0620
Your OPC20 must be zero because SOC is invalid (SYS16-B01 = 0).
0621
Your OPC21 must be zero because SOC is invalid (SYS16-B01 = 0).
0622
Your OPC22 must be zero because SOC is invalid (SYS16-B01 = 0).
0623
Your OPC23 must be zero because SOC is invalid (SYS16-B01 = 0).
0624
Your OPC24 must be zero because SOC is invalid (SYS16-B01 = 0).
0625
Your OPC25 must be zero because SOC is invalid (SYS16-B01 = 0).
0626
Your OPC26 must be zero because SOC is invalid (SYS16-B01 = 0).
0627
Your OPC27 must be zero because TOC is invalid (SYS16-B02 = 0).
0628
Your OPC28 must be zero because TOC is invalid (SYS16-B02 = 0).
0629
Your OPC29 must be zero because TOC is invalid (SYS16-B02 = 0).
0630
Your OPC30 must be zero because TOC is invalid (SYS16-B02 = 0).
0631
Your OPC31 must be zero because TOC is invalid (SYS16-B02 = 0).
0632
Your OPC32 must be zero because TOC is invalid (SYS16-B02 = 0).