Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
Bit
B04-B06
Selected Pressure Control Valve
The module uses its algorithm to drive the following output during any Press/Pos Third Clamp Open Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
B07
Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)
B08-B15
Open
TOC03 - 04
Open
Expert Response Compensation (ERC) Percentage
Word
Description
TOC05
Minimum Velocity Control ERC Percentage [31]
Although error coding allows range of 00000 to 09999, the module limits it to a minimum of 01000.
TOC06
Minimum Pressure Control ERC Percentage [31]
Although error coding allows range of 00000 to 09999, the module limits it to a minimum of 01000.
TOC07
Open
Watchdog Timer
Word
Description
TOC08
Profile Watchdog Timer Preset [21] When the module starts the Third Clamp Open Profile, it:
S
starts an internal Profile Watchdog timer
S
stops the timer and reset accumulated value to zero (after reporting total execution time in OPS59) when it completes the profile
S
sets master status bit SYS04-B12 when the accumulated value of this timer equals or exceeds this entry
A zero entry inhibits SYS04-B12.
Unselected Valve Set-output Values
When the module starts the Third Clamp Open Profile, it:
•
sets its unselected outputs to the values listed below
•
ignores the unselected value of the selected output
•
uses ramp rates TOC17 - TOC32 to ramp unselected outputs
if
then
the module is commanded to start the
Ejector Profile during this TOC Profile
this TOC Profile surrenders control of the
unselected valve that is the selected
Ejector Profile valve
the module is commanded to start this TOC
Profile during the Ejector Profile
the Ejector Profile gives control of all of its
unselected valves to this TOC Profile
Third Clamp Open and Ejector Profiles are
run concurrently
all outputs that are unselected in both
profiles are controlled by this TOC Profile
Word
Description
TOC09
Output #1 Set-output Value during Profile [19]
TOC10
Output #2 Set-output Value during Profile [19]
TOC11
Output #3 Set-output Value during Profile [19]
TOC12
Output #4 Set-output Value during Profile [19]