ID = 9
0727
IPC27 cannot be 00000 because it conflicts with one of:
IPC29 > 00000 when IPC03-B01 = 0
C 9
00000
C03 0
0
IPC30 > 00000 when IPC03-B01 = 1
0728
IPC28 cannot be 00000 when IPC30 > 00000.
0731
IPC31 cannot be 00000 because it conflicts with one of:
IPC33 > 00000 when IPC03-B01 = 0
C33
00000
C03 0
0
IPC34 > 00000 when IPC03-B01 = 1
0732
IPC32 cannot be 00000 when IPC34 > 00000.
0735
IPC35 cannot be 00000 because it conflicts with one of:
IPC37 > 00000 when IPC03-B01 = 0
IPC37 > 00000 when IPC03-B01 = 0
IPC38 > 00000 when IPC03-B01 = 1
0736
IPC36 cannot be 00000 when IPC38 > 00000.
0739
IPC39 cannot be 00000 because it conflicts with one of:
IPC41 > 00000 when IPC03-B01 = 0
C
00000
C03 0
0
IPC42 > 00000 when IPC03-B01 = 1
0740
IPC40 cannot be 00000 when IPC42 > 00000.
0743
IPC43 cannot be 00000 because it conflicts with one of:
IPC45 > 00000 when IPC03-B01 = 0
C 5
00000
C03 0
0
IPC46 > 00000 when IPC03-B01 = 1
0744
IPC44 cannot be 00000 when IPC46 > 00000.
0747
IPC47 cannot be 00000 because it conflicts with one of:
IPC49 > 00000 when IPC03-B01 = 0
C 9
00000
C03 0
0
IPC50 > 00000 when IPC03-B01 = 1
0748
IPC48 cannot be 00000 when IPC50 > 00000.
0757
You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1. This mode of Injection Profile execution does not allow
a 00000 entry for IPC57.
0815
IPC15 must be 00000 when IPC11 = 00000.
0816
IPC16 must be 00000 when IPC12 = 00000.
0819
IPC19 must be 00000 when IPC15 = 00000.
0820
IPC20 must be 00000 when IPC16 = 00000.
0823
IPC23 must be 00000 when IPC19 = 00000.
0824
IPC24 must be 00000 when IPC20 = 00000.
0827
IPC27 must be 00000 when IPC23 = 00000.
0828
IPC28 must be 00000 when IPC24 = 00000.
0831
IPC31 must be 00000 when IPC27 = 00000.
0832
IPC32 must be 00000 when IPC28 = 00000.
0835
IPC35 must be 00000 when IPC31 = 00000.
0836
IPC36 must be 00000 when IPC32 = 00000.
0839
IPC39 must be 00000 when IPC35 = 00000.
0840
IPC40 must be 00000 when IPC36 = 00000.
0843
IPC43 must be 00000 when IPC39 = 00000.
0844
IPC44 must be 00000 when IPC40 = 00000.
0847
IPC47 must be 00000 when IPC43 = 00000.
0848
IPC48 must be 00000 when IPC44 = 00000.
0862
IPC62 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QDC
module does not have access to a connected ram (screw) pressure transducer.
0863
IPC63 must be zero because your bit patterns in MCC02 and MCC03 indicate that the QDC
module has no access to a connected cavity pressure transducer.