3–18
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
Bit
B07
Segment 8 (Third Clamp Open)
B08
Segment 9 (Third Clamp Open)
B09
Segment 1 (Clamp Open Slow)
B10
Segment 2 (Clamp Open Slow)
B11-B15
Open
First Clamp Open Profile Actuals
Word
Description
OPS09
Actual Segment 1 Velocity [07] or [08] Average clamp velocity during last Segment 1.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS10
Actual Segment 1 Pressure [02] Average clamp pressure during last Segment 1.
OPS11
Actual Segment 1 Execution Time [21] Time required for last Segment 1.
OPS12
Actual Segment 2 Velocity [07] or [08] Average clamp velocity during last Segment 2.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS13
Actual Segment 2 Pressure [02] Average clamp pressure during last Segment 2.
OPS14
Actual Segment 2 Execution Time [21] Time required for last Segment 2.
OPS15
Actual Segment 3 Velocity [07] or [08] Average clamp velocity during last Segment 3.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS16
Actual Segment 3 Pressure [02] Average clamp pressure during last Segment 3.
OPS17
Actual Segment 3 Execution Time [21] Time required for last Segment 3.
Second Clamp Open Profile Actuals
Word
Description
OPS18
Actual Segment 4 Velocity [07] or [08] Average clamp velocity during last Segment 4.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS19
Actual Segment 4 Pressure [02] Average clamp pressure during last Segment 4.
OPS20
Actual Segment 4 Execution Time [21] Time required for last Segment 4.
OPS21
Actual Segment 5 Velocity [07] or [08] Average clamp velocity during last Segment 5.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS22
Actual Segment 5 Pressure [02] Average clamp pressure during last Segment 5.
OPS23
Actual Segment 5 Execution Time [21] Time required for last Segment 5
OPS24
Actual Segment 6 Velocity [07] or [08] Average clamp velocity during last Segment 6.
If OPC03-B14 is RESET, the module reports this average in percent velocity.
If OPC03-B14 is SET, it reports it in in.(mm)/s.
OPS25
Actual Segment 6 Pressure [02] Average clamp pressure during last Segment 6.
OPS26
Actual Segment 6 Execution Time [21] Time required for last Segment 6.