Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 191

3–15
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
IPS
Word
Bit
Description
B06
Segment 7
B07
Segment 8
B08
Segment 9
B09
Segment 10
B10
Segment 11
B11-B15
Open
IPS08
CV Low Limit Alarms
The module latches each bit when executing the subject profile segment in closed loop, and drives its algorithm CV to
minimum (0%) in an attempt to control the profile setpoint.
The module unlatches each bit when it completes execution of the subject profile segment in open loop, or in closed
loop without driving its algorithm CV to minimum (0%).
When this bit
is latched ON:
algorithm CV
is maximum during:
B00
Segment 1
B01
Segment 2
B02
Segment 3
B03
Segment 4
B04
Segment 5
B05
Segment 6
B06
Segment 7
B07
Segment 8
B08
Segment 9
B09
Segment 10
B10
Segment 11
B11-B15
Open
Injection Profile Actuals
Word
Description
IPS09
Actual Segment 1 Velocity [05] or [06] Average ram (screw) velocity during last Segment 1.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS10
Actual Segment 1 Pressure [01] Average ram (screw) pressure during last Segment 1.
IPS11
Actual Segment 1 Execution Time [21] Time required for last Segment 1.
IPS12
Actual End of Segment 1 Position [12] Ram (Screw) position at completion of last Segment 1.
IPS13
Actual Segment 2 Velocity [05] or [06] Average ram (screw) velocity during last Segment 2.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS14
Actual Segment 2 Pressure [01] Average ram (screw) pressure during last Segment 2.
IPS15
Actual Segment 2 Execution Time [21] Time required for last Segment 2.
IPS16
Actual End of Segment 2 Position [12] Ram (Screw) position at completion of last Segment 2.
IPS17
Actual Segment 3 Velocity [05] or [06] Average ram (screw) velocity during last Segment 3.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS18
Actual Segment 3 Pressure [01] Average ram (screw) pressure during last Segment 3.
IPS19
Actual Segment 3 Execution Time [21] Time required for last Segment 3.
IPS20
Actual End of Segment 3 Position [12] Ram (Screw) position at completion of last Segment 3.
IPS21
Actual Segment 4 Velocity [05] or [06] Average ram (screw) velocity during last Segment 4.
If IPC03-B14 is RESET, the module reports this average in percent velocity.
If IPC03-B14 is SET, it reports it in in.(mm)/s.
IPS22