3–10
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
Bit
B06
Tip Advance Segment
B07
Open
B08
Full Retract Segment 1
B09
Full Retract Segment 2
B10
Full Retract Segment 3
B11-B15
Open
Ejector Profile Actuals
Word
Description
EPS09
Actual Full Advance Segment 1 Velocity [09] or [10] Average ejector velocity during last Full Advance Segment 1.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS10
Actual Full Advance Segment 1 Pressure [03] Average ejector pressure during last Full Advance Segment 1.
EPS11
Actual Full Advance Segment 1 Execution Time [21] Time required for last Full Advance Segment 1.
EPS12
Actual Full Advance Segment 2 Velocity [09] or [10] Average ejector velocity during last Full Advance Segment 2.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS13
Actual Full Advance Segment 2 Pressure [03] Average ejector pressure during last Full Advance Segment 2.
EPS14
Actual Full Advance Segment 2 Execution Time [21] Time required for last Full Advance Segment 2.
EPS15
Actual Full Advance Segment 3 Velocity [09] or [10] Average ejector velocity during last Full Advance Segment 3.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS16
Actual Full Advance Segment 3 Pressure [03] Average ejector pressure during last Full Advance Segment 3.
EPS17
Actual Full Advance Segment 3 Execution Time [21] Time required for last Full Advance Segment 3.
EPS18 - 20 Reserved
EPS21
Actual Tip Retract Segment Velocity [09] or [10] Average ejector velocity during last Tip Retract Segment.
EPS22
Actual Tip Retract Segment Pressure [03] Average ejector pressure during last Tip Retract Segment.
EPS23
Actual Tip Retract Segment Execution Time [21] Time required for last Tip Retract Segment.
EPS24 - 26 Reserved
EPS27
Actual Tip Advance Segment Velocity [09] or [10] Average ejector velocity during last Tip Advance Segment.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS28
Actual Tip Advance Segment Pressure [03] Average ejector pressure during last Tip Advance Segment.
EPS29
Actual Tip Advance Segment Execution Time [21] Time required for last Tip Advance Segment.
EPS30 - 32 Reserved
EPS33
Actual Full Retract Segment 1 Velocity [09] or [10] Average ejector velocity during last Full Retract Segment 1.
EPS34
Actual Full Retract Segment 1 Pressure [03] Average ejector pressure during last Full Retract Segment 1.
EPS35
Actual Full Retract Segment 1 Execution Time [21] Time required for last Full Retract Segment 1.
EPS36
Actual Full Retract Segment 2 Velocity [09] or [10] Average ejector velocity during last Full Retract Segment 2.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS37
Actual Full Retract Segment 2 Pressure [03] Average ejector pressure during last Full Retract Segment 2.
EPS38
Actual Full Retract Segment 2 Execution Time [21] Time required for last Full Retract Segment 2.
EPS39
Actual Full Retract Segment 3 Velocity [09] or [10] Average ejector velocity during last Full Retract Segment 3.
If EPC03-B14 is RESET, the module reports this average in percent velocity.
If EPC03-B14 is SET, it reports it in in.(mm)/s.
EPS40
Actual Full Retract Segment 3 Pressure [03] Average ejector pressure during last Full Retract Segment 3.
EPS41
Actual Full Retract Segment 3 Execution Time [21] Time required for last Full Retract Segment 3.
EPS42 - 44 Reserved
EPS45 - 52 Open