Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Description
Bit
B12
= 0 Vel/Pos Third Clamp Open Profiles ERC On
= 1 Vel/Pos Third Clamp Open Profiles ERC Off
B13
= 0 Press/Pos Third Clamp Open Profiles ERC On
= 1 Press/Pos Third Clamp Open Profiles ERC Off
B14
= 0 Vel/Pos Clamp Open Slow Profiles ERC On
= 1 Vel/Pos Clamp Open Slow Profiles ERC Off
B15
= 0 Press/Pos Clamp Open Slow Profiles ERC On
= 1 Press/Pos Clamp Open Slow Profiles ERC Off
OPC05 - 08
Open
First Clamp Open Profile Setpoints
Word
Description
OPC09
Segment 1 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp open speed to this setpoint after starting the First Clamp Open Profile
until clamp position reaches the smaller of non-zero OPC11 or OPC61
OPC03-B14 is RESET
reads this parameter in percent velocity
OPC03-B14 is SET
reads it in in.(mm)/s.
OPC10
Segment 1 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point after starting the First Clamp Open Profile until clamp position reaches the smaller of non-zero OPC11 or OPC61.
OPC11
End of Segment 1 Position Setpoint [14]
OPC12
Segment 2 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp open speed to this setpoint from the clamp position OPC11 until clamp
position reaches the smaller of non-zero OPC14 or OPC61
OPC03-B14 is RESET
reads this parameter in percent velocity
OPC03-B14 is SET
reads it in in.(mm)/s
OPC13
Segment 2 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point from the clamp position OPC11 until clamp position reaches the smaller of non-zero OPC14 or OPC61.
OPC14
End of Segment 2 Position Setpoint [14]
OPC15
Segment 3 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp open speed to this setpoint from the clamp position OPC14 until clamp
position reaches the smaller of non-zero OPC17 or OPC61
OPC03-B14 is RESET
reads this parameter in percent velocity
OPC03-B14 is SET
reads it in in.(mm)/s
OPC16
Segment 3 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point from the clamp position OPC14 until clamp position reaches the smaller of non-zero OPC17 or OPC61.
OPC17
End of Segment 3 Position Setpoint [14]
Second Clamp Open Profile Setpoints
Word
Description
OPC18
Segment 4 Velocity Setpoint [07] or [08]
if:
then the module:
you select Vel/Pos profile execution
controls clamp open speed to this setpoint after starting the Second Clamp Open Profile
until clamp position reaches the smaller of non-zero OPC20 or OPC61
OPC03-B14 is RESET
reads this parameter in percent velocity
OPC03-B14 is SET
reads it in in.(mm)/s
OPC19
Segment 4 Pressure Setpoint [02] If you select Press/Pos profile execution, the module controls clamp open pressure to this set-
point after starting the Second Clamp Open Profile until clamp position reaches the smaller of non-zero OPC20 or OPC61.
OPC20
End of Segment 4 Position Setpoint [14]