Tcc - third clamp close configuration block, Tcc – third clamp close configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 170

2–104
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Profile Tuning Constants
Word
Description
SOC49
Proportional Gain for Pressure Control [30]
SOC50
Integral Gain for Pressure Control [27] or [28]
SOC51
Derivative Gain for Pressure Control [26] or [21]
SOC52
Proportional Gain for Velocity Control [28]
SOC53
Feed Forward Gain for Velocity Control [30]
SOC54 -
SOC56
Open
Profile Pressure Alarm Setpoint
Word
Description
SOC57
Profile High Pressure Alarm Setpoint [02] The module compares real-time clamp pressure against this entry when executing the
Second Clamp Open Profile. The module sets alarm status bit SYS06-B10 when clamp pressure equals or exceeds this entry dur-
ing the Second Clamp Open Profile. A zero entry inhibits SYS06-B10.
SOC58 - 64 Open
Bit-mapped Control Words
Word
Bit
Description
TCC01
Block ID = 00000101 (Low byte). High byte reserved for the module. Do not use.
TCC02
Configuration Selections
B00-B02
Selected Velocity Control Valve
The module uses its algorithm to drive the following output during any Vel/Pos Third Clamp Close Profile.
B02 B01 B00
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
B03
Open
B04-B06
Selected Pressure Control Valve
The module uses its algorithm to drive the following output during any Press/Pos Third Clamp Close Profile.
B06 B05 B04
0 0 0 Output #1
0 0 1 Output #2
0 1 0 Output #3
0 1 1 Output #4
1 0 0 Output #5
1 0 1 Output #6
1 1 0 Output #7
1 1 1 Output #8
B07
Pressure Algorithm Selection
= 0 Dependent Gains (ISA)
= 1 Independent Gains (A-B)
B08 - B15
Open
TCC03 - 04
Open
TCC – Third Clamp Close
Configuration Block