Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 246
4–22
Programming Error Codes
Publication 1771-6.5.88 – July 1997
Error Code
Description
ID = 9
0443
IPC43 is out of range.
if:
then:
MCC13 and MCC14
IPC43 must be within 00000
≤
IPC43
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC43 must be within 00000
≤
IPC43
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC43 must be within 00000
≤
IPC43
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC43 must be within 00000
≤
IPC43
≤
MCC10 – MCC09
are both zero
0445
IPC45 is out of range.
When IPC03-B14 = 1, a non-zero IPC45 must be within INC45
≤
IPC45
≤
INC46
0446
IPC46 is out of range.
If non-zero, IPC46 must be within INC41
≤
IPC46
≤
INC42
0447
IPC47 is out of range.
if:
then:
MCC13 and MCC14
IPC47 must be within 00000
≤
IPC47
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC47 must be within 00000
≤
IPC47
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC47 must be within 00000
≤
IPC47
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC47 must be within 00000
≤
IPC47
≤
MCC10 – MCC09
are both zero
0449
IPC49 is out of range.
When IPC03-B14 = 1, a non-zero IPC49 must be within INC45
≤
IPC49
≤
INC46
0450
IPC50 is out of range.
If non-zero, IPC50 must be within INC41
≤
IPC50
≤
INC42
0451
IPC51 is out of range.
When IPC03-B14 = 1, IPC51 must be within 00000
≤
IPC51
≤
INC46
0452
IPC52 is out of range. Valid range is 00000
≤
IPC52
≤
INC42
0457
You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1; however,
IPC03-B01 = 0 and IPC03-B00 = 1; however,
IPC57 is out of range. IPC57 must be within MCC17 < IPC57
≤
MCC18
0458
You have selected Pressure Limited Vel/Pos execution for the Injection Profile by
IPC03-B01 = 0 and IPC03-B00 = 1.
IPC58 is out of range.
if:
then:
MCC13 and MCC14
IPC58 must be within 00000
≤
IPC58
≤
MCC14 – MCC13
are both non-zero
MCC13 is non-zero and
IPC58 must be within 00000
≤
IPC58
≤
MCC10 – MCC13.
MCC14 is zero
MCC13 is zero and
IPC58 must be within 00000
≤
IPC58
≤
MCC14 – MCC09.
MCC14 is non-zero
MCC13 and MCC14
IPC58 must be within 00000
≤
IPC58
≤
MCC10 – MCC09
are both zero