1–26
Abbreviated Command and Status Blocks
Publication 1771-6.5.88 – July 1997
PLC47
N44:403
% output for minimum
PLC48
N44:404
% output for maximum
Profile Tuning Constants
PLC49
N44:405
Proportional gain, pressure control
PLC50
N44:406
Integral gain, pressure control
PLC51
N44:407
Derivative gain, pressure control
PLC52
N44:408
Proportional gain, RPM control
PLC53
N44:409
Integral gain, RPM control
PLC54
N44:410
Derivative gain, RPM control
PLC55-56
N44:411-412
Open
Setpoint for Profile Pressure Alarm
PLC57
N44:413
High pressure alarm
PLC58-64
N44:414-420
RFU
Word
Pro-Set Address
Description
Bit-mapped Control Words
PPC01
B38:28
Block ID 00000000 00001111
PPC02
B38:29
RFU
PPC03
B38:30
Algorithm and logical bridging selections
PPC04
B38:31
Open/closed loop and ERC selections
Setpoints for Plastication Profile
PPC05-08
N44:421-424
RFU
PPC09
N44:425
Segment 1 RPM
PPC10
N44:426
Segment 1 pressure
PPC11
N44:427
End of Segment 1 position
PPC12
N44:428
Segment 1 time
PPC13
N44:429
Segment 2 RPM
PPC14
N44:430
Segment 2 pressure
PPC15
N44:431
End of Segment 2 position
PPC16
N44:432
Segment 2 time
PPC17
N44:433
Segment 3 RPM
PPC18
N44:434
Segment 3 pressure
PPC19
N44:435
End of Segment 3 position
PPC20
N44:436
Segment 3 time
PPC21
N44:437
Segment 4 RPM
PPC22
N44:438
Segment 4 pressure
PPC23
N44:439
End of Segment 4 position
PPC24
N44:440
Segment 4 time
PPC25
N44:441
Segment 5 RPM
PPC26
N44:442
Segment 5 pressure
PPC27
N44:443
End of Segment 5 position
PPC28
N44:444
Segment 5 time
PPC29
N044:445
Segment 6 RPM
PPC30
N44:446
Segment 6 pressure
PPC31
N44:447
End of Segment 6 position
PPC32
N44:448
Segment 6 time
PPC33
N44:449
Segment 7 RPM
PPC34
N44:450
Segment 7 pressure
PPC – Plastication
Profile Block