OSC
End of Profile Set-output Values
When the module completes the Clamp Open Slow Profile and
SYS21-B14 is RESET, it:
•
sets its outputs to the values listed below
•
sets status bit SYS22-B13
•
ignores SYS22 and these values and gives output control to the
Ejector Profile if SYS21-B14 is SET
•
uses ramp rates OSC17 - 32 when changing outputs to these values
Use these values for pulling cores if applied before starting the
Ejector Profile.
Word
Description
OSC33
Output #1 Set-output Value at End of Profile [19]
OSC34
Output #2 Set-output Value at End of Profile [19]
OSC35
Output #3 Set-output Value at End of Profile [19]
OSC36
Output #4 Set-output Value at End of Profile [19]
OSC37
Output #5 Set-output Value at End of Profile [19]
OSC38
Output #6 Set-output Value at End of Profile [19]
OSC39
Output #7 Set-output Value at End of Profile [19]
OSC40
Output #8 Set-output Value at End of Profile [19]
Pressure Control Limits
Word
Description
OSC41
Pressure Minimum Control Limit [02] Minimum controllable clamp pressure attainable during any Press/Pos Clamp Open Slow Pro-
file. The module expects this clamp pressure when setting its selected pressure valve to the %-output in OSC43.
OSC42
Pressure Maximum Control Limit [02] Maximum controllable clamp pressure attainable during any Press/Pos Clamp Open Slow
Profile. The module expects this clamp pressure when setting its selected pressure valve to the %-output in OSC44.
OSC43
Selected Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Clamp Open Slow Profile. The module expects a pressure equal to OSC41 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Clamp Open Slow Profile will be executed as a reverse-act-
ing algorithm if this entry is greater than OSC44.
OSC44
Selected Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected pressure
valve during any Press/Pos Clamp Open Slow Profile. The module expects a pressure equal to OSC42 when setting the selected
pressure valve to this %-output during profile execution. The Press/Pos Clamp Open Slow Profile will be executed as a reverse-act-
ing algorithm if this entry is less than OSC43.
Velocity Control Limits
Word
Description
OSC45
Velocity Minimum Control Limit [08] Minimum controllable clamp velocity attainable during any Vel/Pos Clamp Open Slow Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in OSC47.
OSC46
Velocity Maximum Control Limit [08] Maximum controllable clamp velocity attainable during any Vel/Pos Clamp Open Slow Profile.
The module expects this clamp velocity when setting its selected velocity valve to the %-output in OSC48.
OSC47
Selected Velocity Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected velocity valve
during any Vel/Pos Clamp Open Slow Profile. The module expects a velocity equal to OSC45 when setting the selected velocity
valve to this %-output during profile execution. The Vel/Pos Clamp Open Slow Profile will be executed as a reverse-acting algorithm
if this entry is greater than OSC48.
OSC48
Selected Velocity Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected velocity
valve during any Vel/Pos Clamp Open Slow Profile. The module expects a velocity equal to OSC46 when setting the selected veloc-
ity valve to this %-output during profile execution. The Vel/Pos Clamp Open Slow Profile will be executed as a reverse-acting algo-
rithm if this entry is less than OSC47.