Ptc - process trace configuration block, Ptc – process trace configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 161
![background image](/manuals/579944/161/background.png)
2–95
Command Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
PTC
Movement Pressure Alarm Setpoint
Word
Description
PSC57
Movement High Pressure Alarm Setpoint [01] The module compares real-time ram (screw) pressure against this entry when ex-
ecuting the Post-decompression Movement. The module sets alarm status bit SYS06-B08 when ram (screw) pressure equals or
exceeds this entry during the Post-decompression Movement. A zero entry inhibits SYS06-B08.
PSC58 - 64
Open
Bit-mapped Control Words
Word
Bit
Description
PTC01
Block ID = 00011100 (Low Byte). High byte reserved for the module. Do not use.
PTC02
Control bits
B00
0 = Process trace disabled
1 = Process trace enabled
B01
0 = Trigger on time delay
1 = Trigger on position
PTC03
Open
PTC04
Open
PTC05
Trigger delay (in hundredths of seconds) for data collection after injection begins
(when PTC02-B01 = 0)
PTC06
Trigger position (in hundredths of inches or tenths of millimeters) on which to collect data when PTC02-B01 = 1
PTC07
Sample rate at which the module collects trace data in milliseconds (must be an even number between 2 and 230)
PTC08
Trace #1 selection
B01
Injection position
B02
Injection pressure
B03
Injection velocity
The module will return unscaled injection position data if injection velocity is selected. The process trace screen uses
this position information to calculate and display velocity.
B04
Cavity pressure
B05
Screw RPM
B06
Injection flow valve output
B07
Injection pressure valve output
B08 - B15
Reserved Do not use.
PTC09
Trace #2 selection
B01
Injection position
B02
Injection pressure
B03
Injection velocity
The module will return unscaled injection position data if injection velocity is selected. The process trace screen uses
this position information to calculate and display velocity.
B04
Cavity pressure
B05
Screw RPM
B06
Injection flow valve output
B07
Injection pressure valve output
B08 - B15
Reserved Do not use.
PTC – Process Trace