3–3
Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
In the listings of status blocks, each stored-value word is followed by
a bracketed [ ] 2-digit number code denoting the engineering units
and range associated with the value as shown in the following table:
#Code
Type of Block
Units and Range
01
Ram (Screw)
Pressure (0000.0 to 9999.0 PSI or 000.0 to 999.9 Bar)
02
Clamp
Pressure (0000.0 to 9999.0 PSI or 000.0 to 999.9 Bar)
03
Ejector
Pressure (0000.0 to 9999.0 PSI or 000.0 to 999.9 Bar)
04
Cavity
Pressure (00000.0 to 20000.0 PSI or 0000.0 to 2000.0 Bar)
05
Ram (Screw)
Percent of maximum velocity (00.00 to 99.99%)
07
Clamp
Percent of maximum velocity (00.00 to 99.99%)
09
Ejector
Percent of maximum velocity (00.00 to 99.99%)
06
Ram (Screw)
Velocity along axis (00.00 to 99.99 in. per sec. or 000.0 to 999.9 mm per sec.)
08
Clamp
Velocity along axis (00.00 to 99.99 in. per sec. or 000.0 to 999.9 mm per sec.)
10
Ejector
Velocity along axis (00.00 to 99.99 in. per sec. or 000.0 to 999.9 mm per sec.)
11
Ram (Screw) Measured from zero
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
12
Ram (Screw) Measured from MCC13
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
13
Clamp Axis Measured from zero
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
14
Clamp Axis Measured from MCC27
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
15
Ejector Axis Measured from zero
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
16
Ejector Axis Measured from MCC41
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
17
Measured as noted
Incremental distance (00.00 to 99.99 in. or 000.0 to 999.9 mm.)
18
Measured as noted
Incremental distance (00.00 to 00.99 in. or 000.0 to 009.9 mm.)
19
Percent signal output (00.00 to 99.99%)
20
Percent signal output per second (0000. To 9999.)
21
Time measured in seconds (00.00 to 99.99)
22
Time measured in seconds (000.0 to 999.9)
23
Time measured in seconds (00.00 to 00.99)
24
Input signal range (00.00 to 10.00 or 01.00 to 05.00 or 04.00 to 20.00)
25
Screw rotational speed (000.0 to 999.9 RPM)
26
Time (algorithm) (00.00 to 9.99 minutes)
27
Inverse time (algorithm) (00.00 to 99.99 inverse minutes)
28
Inverse time (algorithm) (00.00 to 99.99 inverse seconds)
31
Percent (00.00 to 99.99%)
The System Status Block (SYS) reports system status.
The module can always return the System Status Block to the host
processor. It returns this block after each block transfer read (BTR)
request from the PLC processor unless the previous block transfer
write (BTW) to the module was a valid dynamic command block
(DYC) containing a request for some other status block.
Engineering Units
Status Block for Reporting
System Status