Eac - ejector advance configuration block, Eac – ejector advance configuration block – Rockwell Automation 1771-QDC PLASTIC MOLD.MODULE User Manual
Page 23
1–5
Abbreviated Command and Status Blocks
Publication 1771-6.5.88 – July 1997
Word
Pro-Set Address
Description
Bit-mapped Control Words
EAC01
B39:0
Block ID 00000000 00010110
EAC02
B39:1
Selected valve configurations
EAC03-04
B39:2-3
RFU
Expert Response Compensation Percentage
EAC05
N45:1
ERC % minimum velocity
EAC06
N45:2
ERC % minimum pressure
EAC07
N45:3
RFU
Watchdog Timer
EAC08
N45:4
Profile timer preset
Set-output Values for Unselected Valves (During Advance)
EAC09
N45:5
Output #1
EAC10
N45:6
Output #2
EAC11
N45:7
Output #3
EAC12
N45:8
Output #4
EAC13
N45:9
Output #5
EAC14
N45:10
Output #6
EAC15
N45:11
Output #7
EAC16
N45:12
Output #8
Acceleration Ramp Rates
EAC17
N45:13
Output #1
EAC18
N45:14
Output #2
EAC19
N45:15
Output #3
EAC20
N45:16
Output #4
EAC21
N45:17
Output #5
EAC22
N45:18
Output #6
EAC23
N45:19
Output #7
EAC24
N45:20
Output #8
Deceleration Ramp Rates
EAC25
N45:21
Output #1
EAC26
N45:22
Output #2
EAC27
N45:23
Output #3
EAC28
N45:24
Output #4
EAC29
N45:25
Output #5
EAC30
N45:26
Output #6
EAC31
N45:27
Output #7
EAC32
N45:28
Output #8
End of Stroke Set-output Values
EAC33
N45:29
Output #1
EAC34
N45:30
Output #2
EAC35
N45:31
Output #3
EAC36
N45:32
Output #4
EAC37
N45:33
Output #5
EAC38
N45:34
Output #6
EAC39
N45:35
Output #7
EAC40
N45:36
Output #8
EAC – Ejector Advance
Configuration Block