2–60

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

Notes: 1. For [ ] engineering units, see page 3.

2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.

Word

Description

IPC37

Segment 8 Velocity Setpoint [05] or [06]
if:

then the module:

you select Vel/Pos

controls ram (screw) forward speed to this setpoint from ram (screw) position IPC35 until ram

profile execution

(screw) position reaches IPC39 (or until transition if sooner)

IPC03-B14 is RESET

reads this parameter in percent velocity

IPC03-B14 is SET

reads it in in.(mm)/s

IPC38

Segment 8 Pressure Setpoint [01]
if:

then the module:

you select Press/Pos

controls ram (screw) pressure to this setpoint from ram (screw) position IPC35 until ram (screw)

profile execution

position reaches IPC39 (or until transition if sooner)

you select Press/Time

controls ram (screw) pressure to this setpoint at completion of Segment 7 for time period IPC40

profile execution

(or until transition if sooner)

IPC39

End of Segment 8 Position Setpoint [12]

IPC40

Segment 8 Time Setpoint [21] If you select Press/Time profile execution, the module controls ram (screw) pressure to setpoint
IPC38 for this time period (or until transition if sooner) beginning at completion of Segment 7.

IPC41

Segment 9 Velocity Setpoint [05] or [06]
if:

then the module:

you select Vel/Pos

controls ram (screw) forward speed to this setpoint from ram (screw) position IPC39 until ram

profile execution

(screw) position reaches IPC43 (or until transition if sooner)

IPC03-B14 is RESET

reads this parameter in percent velocity

IPC03-B14 is SET

reads it in in.(mm)/s

IPC42

Segment 9 Pressure Setpoint [01]
if:

then the module:

you select Press/Pos

controls ram (screw) pressure to this setpoint from ram (screw) position IPC39 until ram (screw)

profile execution

position reaches IPC43 (or until transition if sooner)

you select Press/Time

controls ram (screw) pressure to this setpoint at completion of Segment 8 for time period IPC44

profile execution

(or until transition if sooner)

IPC43

End of Segment 9 Position Setpoint [12]

IPC44

Segment 9 Time Setpoint [21] If you select Press/Time profile execution, the module controls ram (screw) pressure to setpoint
IPC42 for this time period (or until transition if sooner) beginning at completion of Segment 8.

IPC45

Segment 10 Velocity Setpoint [05] or [06]
if:

then the module:

you select Vel/Pos

controls ram (screw) forward speed to this setpoint from ram (screw) position IPC43 until ram

profile execution

(screw) position reaches IPC47 (or until transition if sooner)

IPC03-B14 is RESET

reads this parameter in percent velocity

IPC03-B14 is SET

reads it in in.(mm)/s

IPC46

Segment 10 Pressure Setpoint [01]
if:

then the module:

you select Press/Pos

controls ram (screw) pressure to this setpoint from ram (screw) position IPC43 until ram (screw)

profile execution

position reaches IPC47 (or until transition if sooner)

you select Press/Time

controls ram (screw) pressure to this setpoint at completion of Segment 9 for time period IPC48

profile execution

(or until transition if sooner)

IPC47

End of Segment 10 Position Setpoint [12]

IPC48

Segment 10 Time Setpoint [21] If you select Press/Time profile execution, the module controls ram (screw) pressure to setpoint
IPC46 for this time period (or until transition if sooner) beginning at completion of Segment 9.

IPC49

Segment 11 Velocity Setpoint [05] or [06]
if:

then the module:

you select Vel/Pos

controls ram (screw) forward speed to this setpoint from ram (screw) position IPC47 until transition

profile execution

IPC03-B14 is RESET

reads this parameter in percent velocity

IPC03-B14 is SET

reads it in in.(mm)/s