Status Word/Bit Descriptions
Publication 1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Bit
Description
SYS15
Status of On-board Command Blocks
The module latches bits individually when it successfully decodes the referenced command block and places new data
into operational memory. The module does not latch any bit associated with an unrecognizable command block.
The module unlatches all bits in this word:
S
on power start-up, or
S
when it receives a new MCC for decode
When this bit
is latched ON:
this on-board block is valid:
B00
MCC
B01
JGC
B02
FCC
B03
SCC
B04
TCC
B05
LPC
B06
CPC The module also unlatches this bit when it successfully decodes a new FCC, SCC, TCC, or LPC.
B07
INC
B08
IPC The module also unlatches this bit when it successfully decodes a new INC.
B09
PKC
B10
HDC
B11
HPC The module also unlatches this bit when it successfully decodes a new PKC or HDC.
B12
PRC
B13
PLC
B14
PPC The module also unlatches this bit when it successfully decodes a new PLC.
B15
PSC
SYS16
Status of On-board Command Block
The module latches bits individually when it successfully decodes the referenced command block and places new data
into operational memory. The module does not latch any bit associated with an unrecognizable command block.
The module unlatches all bits in this word on power start-up or when it receives a new MCC for decoding.
When this bit
is latched ON:
this on-board block is valid:
B00
FOC
B01
SOC
B02
TOC
B03
OSC
B04
OPC The module also unlatches this bit when it successfully decodes a new FOC, SOC, TOC, or OPC.
B05
EAC
When this bit
is latched ON:
this on-board block is valid:
B06
ERC
B07
EPC The module also unlatches this bit when it successfully decodes a new EAC or ERC.
B08
DYC
B09
RLC
B10
CLC
B11
PTC
B12-B15
Open