2–49

Command Word/Bit Descriptions

Publication 1771-6.5.88 – July 1997

HDC

End of Profile Set-output Values

When the module completes the Hold Profile and HPC03-B08 is SET, it:

sets its outputs to the following values

sets status bit SYS22-B06

uses ramp rates HDC17 - 32 when changing outputs to these values

Word

Description

HDC33

Output #1 Set-output Value at End of Profile [19]

HDC34

Output #2 Set-output Value at End of Profile [19]

HDC35

Output #3 Set-output Value at End of Profile [19]

HDC36

Output #4 Set-output Value at End of Profile [19]

HDC37

Output #5 Set-output Value at End of Profile [19]

HDC38

Output #6 Set-output Value at End of Profile [19]

HDC39

Output #7 Set-output Value at End of Profile [19]

HDC40

Output #8 Set-output Value at End of Profile [19]

Ram (Screw) Pressure Control Limits

Word

Description

HDC41

Ram (Screw) Pressure Minimum Control Limit [01] Minimum controllable ram (screw) pressure attainable during any Ram Press/
Time Hold Profile. The module expects this ram (screw) pressure when setting its selected ram (screw) pressure valve to the %-out-
put in HDC43.

HDC42

Ram (Screw) Pressure Maximum Control Limit [01] Maximum controllable ram (screw) pressure attainable during any Ram Press/
Time Hold Profile. The module expects this ram (screw) pressure when setting its selected ram (screw) pressure valve to the %-out-
put in HDC44.

HDC43

Selected Ram (Screw) Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the se-
lected pressure valve during any Ram Press/Time Hold Profile. The module expects a pressure equal to HDC41 when setting the
selected ram (screw) pressure valve to this %-output during profile execution. Ram Press/Time Hold Profile will be executed as a
reverse-acting algorithm if this entry is greater than HDC44.

HDC44

Selected Ram (Screw) Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the
selected pressure valve during any Ram Press/Time Hold Profile. The module expects a pressure equal to HDC42 when setting the
selected ram (screw) pressure valve to this %-output during profile execution. Ram Press/Time Hold Profile will be executed as a
reverse-acting algorithm if this entry is less than HDC43.

Cavity Pressure Control Limits

Word

Description

HDC45

Cavity Pressure Minimum Control Limit [04] Minimum controllable cavity pressure attainable during any Cav Press/Time Hold Pro-
file. The module expects this cavity pressure when setting its selected cavity pressure valve to the %-output in HDC47.

HDC46

Cavity Pressure Maximum Control Limit [04] Maximum controllable cavity pressure attainable during any Cav Press/Time Hold Pro-
file . The module expects this cavity pressure when setting its selected cavity pressure valve to the %-output in HDC48.

HDC47

Selected Cavity Pressure Valve Output for Minimum [19] 0% CV output percentage that the module uses to drive the selected pres-
sure valve during any Cav Press/Time Hold Profile. The module expects a pressure equal to HDC45 when setting the selected
cavity pressure valve to this %-output during profile execution. The Cav Press/Time Hold Profile will be executed as a reverse-acting
algorithm if this entry is greater than HDC48.

HDC48

Selected Cavity Pressure Valve Output for Maximum [19] 100% CV output percentage that the module uses to drive the selected
pressure valve during any Cav Press/Time Hold Profile. The module expects a pressure equal to HDC46 when setting the selected
cavity pressure valve to this %-output during profile execution. The Cav Press/Time Hold Profile will be executed as a reverse-acting
algorithm if this entry is less than HDC47.