Trend State
Value indicates the state of the Data Trend function.
• Value 0 - Wait Enable indicates the trend function is ready and waiting to begin data collection. Setting bit
0 “Enbl Collect” of
[Trend Control] will cause data collection to begin. In this state,
[TrendBuffPointer] and the Trend Output Parameters are active.
• Value 1 - First Scan indicates the Trend function is executing the first pass through the trend sample buffer.
This takes 512 ms. (0.5 ms x 1024 samples). When it enters this state, the Trend function clears bit 1
“Triggered” and 2 “Complete” bits of
[Trend Status]. While in this state, the Trend function
refreshes the data. Also while in this state, the function forces the Trend Output parameters to zero. When
done, it enters the Pre-trigger state.
• Value 2 - Pre-trigger indicates the Trend function is sampling the trend inputs and storing them in
memory, at a rate determined by
[Trend Rate]. Sampling continues until either the trend trigger
event occurs or bit 0 “Enbl Collect” of
[Trend Control] is cleared. While in this state, the Trend
function forces the Trend Output parameters to zero. If the trigger event occurs, the function sets bit 1
“Triggered” of
[Trend Status] and enters the Post-trigger state. If bit 0 “Enbl Collect” of Parameter
556 [Trend Control] is cleared, the function sets bit 2 “Complete” of Par 557 [Trend Status] and returns to
the Wait Enable state.
• Value 3 - Post-trigger indicates the Trend function is continuing to sample and save the trend inputs until
the buffer is full. While in this state, the function forces the Trend Output parameters to zero value. When
the buffer is full, the function sets bit 2 “Complete” of
[Trend Status] and enters the Wait Disable
state.
• Value 4 - Wait Disable indicates the Trend function is complete and waiting for bit 0 “Enbl Collect” of
[Trend Control] to be cleared. When this is done, the trend function returns to the Wait Enable state.
While in the Wait Disable state,
[TrendBuffPointer] and the Trend Output Parameters are active.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
4 =
“Wait Enable”
“Wait Enable”
“First Scan”
“Pre-trigger”
“Post-trigger”
“Wait Disable”
559
Trend Rate
Sets the sample time for both trend input and output updates.
Default:
Min/Max:
Units:
0.5000
0.5000/1000.0000
ms
Y
RW Real
560
Trend TrigA DInt
Provides the integer input for the A trigger function. This integer is converted to a real number and summed
with
[Trend TrigA Real]. The result is compared with the Trigger B sum. If the A sum exceeds the B sum,
then a trend trigger will occur.
Default:
Min/Max:
0
-/+2147483648
Y
RW 32-bit
Integer
561
Trend TrigA Real
Provides the real input for the A trigger function. This real number is summed with
[Trend TrigA Int].
The result is compared with the Trigger B sum. If the A sum exceeds the B sum, then a trend trigger will occur.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Y
RW Real
562
Trend TrigB DInt
Provides the integer input for the B trigger function. This integer is converted to a real number and summed
with
[Trend TrigB Real]. The result is compared with the Trigger A sum. If the A sum exceeds the B sum,
then a trend trigger will occur.
Default:
Min/Max:
0
-/+2147483648
Y
RW 32-bit
Integer
563
Trend TrigB Real
Provides the real input for the B trigger function. This real number is summed with
[Trend TrigB Int].
The result is compared with the Trigger A sum. If the A sum exceeds the B sum, then a trend trigger will occur.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Y
RW Real
564
Trend Trig Data
This is the logic input for the Trend Trigger Function. A trigger will occur on the rise of the specified bit in this
word. The bit will be specified by
[Trend Trig Bit].
Default:
Min:
Max:
00000000000000000000000000000000
00000000000000000000000000000000
11111111111111111111111111111111
Y
RW 32-bit
Boolean
565
Trend Trig Bit
Specifies the bit in
[Trend Trig Data] that will cause a Trend Trigger to occur. Positive numbers specify
rising edges and negative numbers specify falling edges.
Default:
Min/Max:
0
-32/31
Y
RW 16-bit
Integer
566
Trend PreSamples
Specifies the number pre-trigger samples in the trend buffer. Pre-trigger samples are the samples that occur
before the trigger and remain in the buffer. The remainder of the trend buffer will contain post-trigger
samples.
Default:
Min/Max:
511
0/1022
Y
RW 16-bit
Integer
567
Trend Mark DInt
Marks the start of data for trend buffers that are using integer data. The Trend Marker can be used to provide a
scope trigger signal for the Auto Output function.
Default:
Min/Max:
0
-/+2147483648
Y
RW 32-bit
Integer
568
Trend Mark Real
Marks the start of data for trend buffers that are using real data. The Trend Marker can be used to provide a
scope trigger signal for the Auto Output function.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Y
RW Real
569
TrendBuffPointer
Selects the trend buffer element to be displayed in the Trend Output Parameters when the trend function is
inactive (not collecting data samples). A zero value points to the element that corresponds to the trigger event.
Negative values point to pre-trigger data. Positive values point to post-trigger data. When the Auto Output
function is running, this parameter will automatically sequence through it's full range, at a rate set by
[Trend Rate].
Default:
Min/Max:
0
-/+1023
Y
RW 16-bit
Integer
570
Trend In1 DInt
Provides integer input to the Trend 1. The Trending function samples this parameter for Trend Buffer 1, if bit 1
“In 1 Real” is cleared.
Default:
Min/Max:
0
-/+2147483648
Y
RW 32-bit
Integer
No.
Name
Description
Values
Link
able
Re
ad
-Write
Da
ta
T
yp
e
Val 2
Pre-Trigger
Val 0
Wait Enable
Val 1
First Scan
Val 3
Post-Trigger
Val 4
Wait Disable
Enbl Collect
Enbl Collect
Done
Trigger Event
Buffer Full
Enbl Collect