Di a gno s tic tool s, Trending pe a k detect, T as k 3 ) (t as k 1 ) – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual
Page 196: Diagnostic_tools.eps

196
Rockwell Automation Publication 20D-PM001C-EN-P - July 2013
Appendix C
Control Block Diagrams
S
etting
b
it 15
of
p
556
c
aus
e
s
the
trend d
a
ta
to
au
to pl
a
y
ba
ck
a
t the
ra
te entered p
559
(milli
s
econd
s
).
1
) p
566
s
elect
s
the n
u
m
b
er of d
a
ta
point
s
to
s
tore prior to the trend
trigger (
pre
-trigger
d
a
ta
).
2
) p
567
or p
568
,
depending on the
d
a
ta
type of the trend d
a
ta
,
determine
s
the m
a
rker v
a
lu
e pl
a
ced
in the trend d
a
ta
a
t the
b
eginning of
the pre
-trigger d
a
ta
(
trigger
point
-
p
566 -
1
).
3
) Pre
-trigger d
a
ta
i
s
loc
a
ted
a
t
neg
a
tive pointer v
a
lu
e
s
from
[-
p
566
]
to -
1
4
) The trigger point d
a
ta
v
a
lu
e i
s
loc
a
ted
a
t p
569
pointer v
a
lu
e 0
5)
P
o
s
t-
trigger d
a
ta
i
s
loc
a
ted in
po
s
itive pointer v
a
lu
e
s
from
0
to
[+
p
566
]
Di
a
gno
s
tic Tool
s
569
556
1
568
567
Trend Control
(In 1
Re
a
l)
Trend M
a
rk DInt
Trend TrigA DInt
Trend
S
ta
tus
(Triggered
)
Trend Control
(E
n
b
l Collect
)
Trend Trig Bit
Trend Trig D
a
ta
Trend TrigB Re
a
l
Trend TrigB DInt
Trend TrigA Re
a
l
1
2
3
4
5
6
B
A
D
C
F
E
H
G
I
Trend
S
ta
tus
(Complete
)
571
570
572
573
Trend O
u
t1 DInt
Trend O
u
t1
R
e
a
l
Trend In
1
DInt
0
1
Trend In
1
Re
a
l
0
1
575
574
576
577
Trend O
u
t2 DInt
Trend O
u
t2
R
e
a
l
Trend In
2
DInt
0
1
Trend In
2
Re
a
l
0
1
579
578
580
581
Trend O
u
t3 DInt
Trend O
u
t3
R
e
a
l
Trend In
3
DInt
0
1
Trend In
3
Re
a
l
0
1
583
582
584
585
Trend O
u
t4 DInt
Trend O
u
t4
R
e
a
l
Trend In
4
DInt
0
1
Trend In
4
Re
a
l
0
1
TrendB
u
ffPointer
566
Trend Pre
Sa
mple
s
568
567
Trend M
a
rker DInt
Trend M
a
rker Re
a
l
569
TrendB
u
ffPointer
556
15
Trend Control
(A
u
to O
u
tp
u
t)
559
Trend R
a
te
560
561
562
563
>
OR
564
565
S
R
S
R
556
0
B
u
ffer F
u
ll
557
1
557
2
0
.
.
.
.
.
.
.
.
.
.
1023
0
.
.
.
.
.
.
.
.
.
.
1023
0
.
.
.
.
.
.
.
.
.
.
1023
0
.
.
.
.
.
.
.
.
.
.
1023
Trend M
a
rk Re
a
l
214
212
213
210
2
Pe
a
kDtct
S
ta
tus
(P
e
a
k 1
Chng
)
PkDtct
1 In
Re
a
l
PkDtct
1 In
DInt
Pe
a
kDtct Ctrl In
(P
e
a
k1
S
elHigh
)
Pe
a
kDtct
1 Pre
s
et
Pe
a
k Detect
1
O
u
t
Pe
a
kDtct Ctrl In
(P
e
a
k 1
Hold
)
∑
Pe
a
kDtct Ctrl In
(P
e
a
k 1
S
et
)
211
0
210
1
210
0
215
Pe
a
k Detect
218
216
217
210
6
Pe
a
kDtct
S
ta
tus
(P
e
a
k 2
Chng
)
PkDtct
2 In
Re
a
l
PkDtct
2 In
DInt
Pe
a
kDtct Ctrl In
(P
e
a
k2
S
elHigh
)
Pe
a
kDtct
2 Pre
s
et
Pe
a
k Detect
2
O
u
t
Pe
a
kDtct Ctrl In
(P
e
a
k 2
Hold
)
Pe
a
kDtct Ctrl In
(P
e
a
k 2
S
et
)
211
1
210
5
210
4
219
Pe
a
k Detect
Trending
Pe
a
k Detect
556
2
Trend Control
(In 2
Re
a
l)
556
3
Trend Control
(In 3
Re
a
l)
556
4
Trend Control
(In 4
Re
a
l)
(T
as
k 3
)
(T
as
k 1
)
NOTE:
The ch
a
nge
b
it, Pe
a
k x Chng (where x = 1 or 2), i
s
s
et TRUE if the pe
a
k detect v
a
lu
e ch
a
nge
s
, otherwi
s
e
the ch
a
nge
b
it i
s
s
et FAL
S
E. Ch
a
nge i
s
a
ls
o
s
et
to FAL
S
E if the detector i
s
in HOLD or
S
ET.
∑
∑
∑
diagnostic_tools.eps