Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

119

Programming and Parameters

Chapter 2

910

SL Tx Comm Format

Defines the node's communication format for transmitting SynchLink data. This determines the number of axis
data words, direct data words and buffered data words transmitted. Configure the format by using the Peer
Communication window in the DriveExecutive™ programming software.
• Value 14 can be used to allow the drive to transmit position data that can be used as a position reference.
Note: Option 14 was added and this parameter was changed to non-linkable for firmware version 3.001.

911

912

913

914

SL Tx DirectSel0

Determines the source type for the data transmitted by direct transmit word 0. The source type
selections are: no data, event, feedback and drive parameter.

SL Tx DirectSel1

Determines the source type for the data transmitted by direct transmit word 1. The source type
selections are: no data, event, feedback and drive parameter.

SL Tx DirectSel2

Determines the source type for the data transmitted by direct transmit word 2. The source type
selections are: no data, event, feedback and drive parameter.

SL Tx DirectSel3

Determines the source type for the data transmitted by direct transmit word 3. The source type
selections are: no data, event, feedback and drive parameter.
Note: These parameters were changed to non-linkable for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =
13 =

“No Data”

“No Data”

14 = “Reserved”

“SL Multiply”

15 = “Reserved”

“Event P0”

16 = “Reserved”

“Event P1”

17 = “Reserved”

“Reserved”

18 = “Reserved”

“Reserved”

19 = “Reserved”

“Reserved”

20 = “Reserved”

“Reserved”

21 = “Dir Tx Data”

“Reserved”

22 = “Dir Rx Data”

“Reserved”

23 = “E0 Accum”

“Event Status”

24 = “E1 Accum”

“Reserved”

25 = “Opt0 Accum”

“Reserved”

26 = “Opt1 Accum”

“Reserved”

915

916

SL Rcv Events

Displays the received event status from

Par 917

[SL Rx P0 Regis].

SL Clr Events

Set these bits to clear the corresponding event latches indicated in

Par 915

[SL Rcv Events].

917

SL Rx P0 Regis

Displays received port 0 registration data, if direct received data is configured to be port 0 registration data by the
Rx Direct Data Selector (Parameters

905

909

). Configure this selection by using the Peer Communication

window.

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

918

SL Rx P1 Regis

Displays received port 1 registration data, if direct received data is configured to be port 1 registration data by the
Rx Direct Data Selector (Parameters

905

909

). Configure this selection by using the Peer Communication

window.

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

921

SL Real2DInt In

Provides the floating point (real) input to the real to integer conversion function.

Default:
Min/Max:

0.0000
-/+16.0000

Y

RW Real

922

SL Real2DInt Out

Displays the integer output of the real to integer conversion function. The value is the result of the formula:

Par 921

[SL Real2DInt In] x

Par 923

[SL Mult Base].

Default:
Min/Max:

0
0/65535

RO 16-bit

Integer

923

SL Mult Base

Specifies the base for SynchLink real to integer and integer to real conversion functions. Determines the
resolution of the conversion results. You must use the same value at the transmitting node and receiving /
multiplying nodes. Enter a value that will not produce an overflow - the product of this value and the inputs to
the conversion and multiply functions must be less than 65,536.

Default:
Min/Max:

10000.0000
0.2000/50000.0000

RW Real

924

SL Mult A In

Displays the A Multiplier Input, as a floating point (real) value. This value is divided by the

Par 923

[SL Mult Base].

The source of the A Multiplier is determined by the Rx Direct Data Selector (Parameters

905

-

909

). The possible

sources are: zero,

Par 1054

[MulDiv 1 Mul],

Par 1056

[MulDiv 1 Result],

Par 1058

[MulDiv 2 Mul], or

Par 1060

[MulDiv 2 Result]. The SynchLink Multiply function takes this input before it is converted to floating point.

Default:
Min/Max:

0.0000
0.0000/65535.0000

RO Real

925

SL Mult B In

The B Multiplier Input. This must be a floating point (real) value. The SynchLink Multiply function takes this input
after it is converted to integer.

Default:
Min/Max:

1.0000
0.25000/2.0000

Y

RW Real

926

SL Mult Out

Displays the output of the SynchLink Multiply function as a floating point (real) value. The value is the result of
the formula:

Par 924

[SL Mult A In] source (integer) x

Par 925

[SL Mult B In] /

Par 923

[SL Mult Base] or Par

924 [SL Mult A In] x Par 925 [SL Mult B In].
Note: The SynchLink Multiply function produces an output that is always positive.

Default:
Min/Max:

0.0000
0.0000/65535.0000

RO Real

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

Value

Axis (A)

Direct (D)

Buffered (B)

Options

0

0

0

0

7

0

2

18

9

0

4

8

14

1

3

14

17

0

4

18

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Op

t0 R

eg

is

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

E1

R

eg

is

E0

R

eg

is

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

0

x

x

x

x

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True