beautypg.com

MTS FlexTest Models 200 User Manual

Page 86

background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 494.44 Two-Station System Board

FlexTest Controller Configurations

86

Interlock Input

Interlock Trip
Voltage

Maximum Input
Voltage

Input Resistance

Interlock Power
Output

Connector J43 A/B (D9S) (one per J43 connector)

0.8 V minimum, 3 V maximum

+26 V DC

2700

Ω

+24 V DC (current limited by a 15-K

Ω resistor)

Load Frame
E-Stop

Crosshead Unlock
Output

Program Interlock
Input

Connector J29A and J29B (D15S)

24 V DC at 1 A

Switch Contact Closed = no program interlock
Switch Contact Open = program interlock

HPU Outputs
(Start/Low/High)

HPU Outputs
(start, low, high)

HPU ON Input

Connector J25 (D15P)

Output Voltage: 24 V DC at 250 mA

Trip Voltage: 0.8–10.0 V DC

Maximum Input Voltage: +26 V DC

HPU Interlock
Inputs (Low Level
and Overtemp)

Trip-point Voltage

Connector J25 (D15P)

0.8–10.0 V DC
Maximum Input Voltage: +26 V DC

Model 494.44 Specifications (part 2 of 3)

P

ARAMETER

S