MTS FlexTest Models 200 User Manual
Page 260
![background image](/manuals/567928/260/background.png)
MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 493.80 Encoder Interface Board
Digital I/O and Transition Boards
260
Mode Settings for the Model 493.80 Encoder Interface Board
Each channel on the Model 493.80 board includes jumpers that you can
configure for various modes.
Note
When used with the Model 494.49 Quad Encoder board, the jumper
setting for each channel’s mode must be the same (all SSI or all
non-SSI).
Mode settings include:
•
SSI devices–such as Temposonics R transducers, Gurley and other
absolute encoders
•
Non-SSI devices–such as incremental encoders, and PWM devices
such as Temposonics G transducers.
493.80 Encoder Interface Board
Mode Settings
X19
Channel 1
= Non-SSI Device
Channel 2
Channel 3
Channel 4
= SSI Device
J3
J4
J5
J6
X3
X4
X5 X6
J11
J12
X7
X8
X9 X10
X1
1
X12
X13 X14
X15
X16
X17
X18
X19
Mode Settings for use with
Model 494.49 Quad Encoder Card
X19
= SSI Devices
= Non-SSI Devices
X19