beautypg.com

Jumper settings – MTS FlexTest Models 200 User Manual

Page 276

background image

MTS FlexTest® Models 40/60/100/200 Controller Hardware

Model 493.07 HPU Converter Box

Digital I/O and Transition Boards

276

When connected to a 120-volt HPU, the Model 493.07 Converter Box
contains dangerous voltages.

Removing the cover from the Model 493.07 Converter Box without first
disconnecting all cables can expose you to a dangerous electrical
shock hazard that can cause series personal injury or death.

Disconnect all cables from the Model 493.07 Converter Box before removing
the cover.

Jumper settings

As shipped, the HPU interface on the Model 493.07 Converter Box is
compatible with Model 458.10/.20, 490.01, 493.xx, 494.xx, and 497.05
components.

The following figure shows the main components of the Model 493.07
Converter Box, including connectors and jumpers.

WARNING

To 493.42

System I/O

Module (J25)

(Shown with cover removed)

J1

J25

To HPU

E16 E12

E17 E13

E10

E11

E14

E15