Jumper settings – MTS FlexTest Models 200 User Manual
Page 276

MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 493.07 HPU Converter Box
Digital I/O and Transition Boards
276
When connected to a 120-volt HPU, the Model 493.07 Converter Box
contains dangerous voltages.
Removing the cover from the Model 493.07 Converter Box without first
disconnecting all cables can expose you to a dangerous electrical
shock hazard that can cause series personal injury or death.
Disconnect all cables from the Model 493.07 Converter Box before removing
the cover.
Jumper settings
As shipped, the HPU interface on the Model 493.07 Converter Box is
compatible with Model 458.10/.20, 490.01, 493.xx, 494.xx, and 497.05
components.
The following figure shows the main components of the Model 493.07
Converter Box, including connectors and jumpers.
WARNING
To 493.42
System I/O
Module (J25)
(Shown with cover removed)
J1
J25
To HPU
E16 E12
E17 E13
E10
E11
E14
E15