Typical model 494.04 chassis connections – MTS FlexTest Models 200 User Manual
Page 51

FlexTest 40 Controller Configuration
MTS FlexTest® Models 40/60/100/200 Controller Hardware
FlexTest Controller Configurations
51
Typical Model 494.04 Chassis Connections
HPU
Power
100-240 VAC
50-60 Hz, 1-2 A
DA Output
J24
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
J54 Dig In
J49
Aux Pwr
J25 Hpu
Dig Out J55
Intlk J43
E-stop J29
J28 HSM
LAN 2
LAN 1
DEBUG
MOT
OROLA
10/100 BASE T 10/100 BASE T
SCSI
BUSY
PIB
BUSY
PCI MEZZANINE CARD
PCI MEZZANINE CARD
Slot 3 - 494.40 I/O Carrier
Slot 2 - 494.40 I/O Carrier
Slot 1 - Processor Board
Force Transducer
Hydraulic
Service
Manifold
(HSM)
Hydraulic
Power Unit
(HPU)
Computer
Workstation
Load
Frame
E-Stop
Servovalve
J49 AUX PWR
Auxilliary DC
supply voltages
for external
devices. + 5 V
DC, +15 V DC,
-15 V DC,
+24 V DC
Slot 4-5
494.41 System I/O
J43 Interlock
Input/Output
J55
Digital
Outputs
J54
Digital
Inputs (3)
Analog
Outputs (2)
J24
Remote
E-Stop
To Digital Universal Conditioner
(DUC) Card in 494.40 I/O Carrier
LVDT
To Valve Driver
Card in 494.40
I/O Carrier