60
J29 Emergency Stop Connections for the Model 494.41 System Board
Connector J29 E-STOP provides an output to external devices when an
emergency stop signal is generated. You can also connect an external E-Stop to
the J29 connector.
Cable specification
To maintain EMC compliance, the J29 E-STOP cable must comply with the
following specifications:
Connector type–15-pin, type D, male EMI connector.
Backshell–EMI metallized plastic or metal.
Cable–18 AWG, 8-conductor with foil shield, with the drain wire connected to a
metallized plastic backshell at the chassis.
Jumper plug required
If connector J29 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 100-007-947 or jumper
pins 3-4, 5-7, 8-13, and 11-15.
Controller Interlock
Open = Controller Interlock
494.41 System Board
Power
100-240 VAC
50-60 Hz, 1-2 A
DA Output
J24
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
J54 Dig In
J49
Aux Pwr
J25 Hpu
Dig Out J55
Intlk J43
E-stop J29
J28 HSM
LAN 2
LAN 1
DEBUG
MOT
OROLA
10/100 BASE T 10/100 BASE T
SCSI
BUSY
PIB
BUSY
PCI MEZZANINE CARD
PCI MEZZANINE CARD
Fused 24 V DC
to Crosshead
J29
E Stop
1
4
3
2
7
5
8
13
12
14
Crosshead Interlock
Common
+24V
External Program
Interlock Source
Open=Program Interlock
HPU E Stop
+24V
HSM High
Crosshead Unlock Power
Crosshead Unlock
Power Common
J29 E-Stop
To HPU E Stop Chain
* MTS Model 505 Pumps and older do not use the
HPU E-Stop 2 signal.