Controller compatibility – MTS FlexTest Models 200 User Manual
Page 280

MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 493.07 HPU Converter Box
Digital I/O and Transition Boards
280
Controller
compatibility
You can mix Model 493.07, 458, 490, and 497.05 Controllers directly on the
same HPU (without the use of an HPU isolation box).
You cannot mix Model 493.07, 458, 490, and/or 497.05 Controllers with
436, 413.05, or 413.8x Controllers unless you use an isolation box.
You can jumper the Model 493.07 Converter box so you can use it directly
with 436 and 413.05 Controllers. You must use an isolation box if you
attempt to use the converter box with Model 458, 490, and 497.05
Controllers.
HPU
493.07
Converter Box
J25
HPU
J1
HPU
J25
HPU
494
Chassis
039-713-8XX (24 V DC)
039-714-6XX (115 V AC)
039-710-7XX (24 V DC)
039-710-8XX (115 V AC)
458* or
490.01*
497.05*
039-708-7xx (24 V DC)
039-708-8xx (115 V AC)
High-Level Y Cable
005-407-801 (24 V DC)
005-401-801 (115 V AC)
* For standard Model 493.07 Converter Box jumper setting only. Alternate settings are required for Model
436.11 and 413.05 Controllers.