MTS FlexTest Models 200 User Manual
Page 235

Model 494.33 Digital I/O Power Supply
MTS FlexTest® Models 40/60/100/200 Controller Hardware
Digital I/O and Transition Boards
235
Power Connections for the Model 494.32 DI/O Breakout Box
To maintain EMC compliance, power cables must comply with the
following specifications.
Note
The maximum cable length for all power cables is 6 m (20 ft).
For cable pin assignments, see
“Power Connections Model 494.32 DI/O
Breakout Box”
on page 236.
Output Pwr cable
Input Pwr cable
Model 494.32 DI/O
Breakout Box
P
ARAMETER
T
O
J1, 494.33 P
OWER
S
UPPLY
T
O
P29, 494.32 B
REAKOUT
B
OX
Connector
4-contact, PT male connector 5-power contact, type D,
female EMI connector
Backshell
Non-conductive with strain
relief
EMI metallized plastic or
metal
Cable
16 AWG, 4-conductor with braided shield connected to the
backshell at the DI/O breakout box only.
P
ARAMETER
T
O
J1, 494.33 P
OWER
S
UPPLY
T
O
J3, 494.32 B
REAKOUT
B
OX
Connector
9-contact, type D, male EMI
connector
15-contact, type D, female
EMI connector
Backshell
EMI metallized plastic or metal
Cable
18 AWG, 4-conductor with braided shield connected to the
backshell at the DI/O breakout box only.