Improper grounding can result in unexpected actuator movement and
failure to meet EMC emission and susceptibility requirements.

Unexpected actuator movement can result in injury or death and/or damage
to the equipment.

Ensure that each controller chassis is properly grounded.

Stand-alone ground

connections

For stand-alone mounting, connect the shorting bar to both ground lugs. Tighten
the two nuts that secure the shorting bar to the ground lugs.

Console ground

connections

If you mount a Series 494 Chassis in a console, remove the shorting bar from the
chassis ground lugs and connect the chassis ground to the console rail as shown.

The chassis ground connects to the AC power ground through the power cord.
The power cord must be plugged into both the chassis and the power source for
proper grounding.

WARNING

100-240 VAC

50-60 Hz, 12/6A

9 8 7 6 5 4 3 2 1 B A

10

SERVICE

493.73

HPU

J23

E-STOP OUT

J24

E-STOP IN

J25 HPU

J54

SYS D I/O

J49 AUX PWR

J3A STA

J3B STA

J28A HSM

J28B HSM

494.74

HSM

J49 AUX PWR

J3A STA

J3B STA

J28A HSM

J28B HSM

494.74

HSM

First

494.75

ANALOG

INPUT

CH 1 - 8

Last

J11

J12

First

494.76

ANALOG

OUTPUT

CH 1 - 8

Last

J11

J12

Power

Over

Temp

Power

OK

J39 Power Monitor

J49 AUX PWR

J3A STA

J3B STA

J28A HSM

J28B HSM

494.74

HSM

J49 AUX PWR

J3A STA

J3B STA

J28A HSM

J28B HSM

494.74

HSM

Series 494 Chassis (Rear)

Shorting Bar

Required

Signal common cable (part number 376-
999-xx) connected to other components.

Chassis ground connects to
AC power ground through the
power cord.