Jumper plug required, Cable specification, J49 auxiliary power – MTS FlexTest Models 200 User Manual
Page 79

Model 494.42 Single-Station System Board
MTS FlexTest® Models 40/60/100/200 Controller Hardware
FlexTest Controller Configurations
79
Jumper plug required
If connector J43 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 100-057-245, or jumper
pins: 1-2, 3-4, and 5-9.
J49 Auxiliary Power Connections for the Model 494.42 System Board
The J49 Aux Pwr connector provides fused (self resetting) auxiliary power
outputs for: +5 V DC, +15 V DC, -15 V DC, and +24 V DC.
Cable specification
To maintain EMC compliance, the J49 Auxiliary Power cable must comply with
the following specifications:
Connector type–9-pin, type D, male EMI connector.
Backshell–EMI metallized plastic or metal.
Cable–AWG and number of conductors as required. Braided shield with shield
connected to the metallized backshell at the chassis.
494.42 System Board
+24 V
-15V
+ 15 V
+24 V
Gnd (+24 V)
+5V
J49 Aux Pwr
1
6
2
7
3
4
5
8
9
Gnd (+/- 15 V)
Gnd (+/- 15 V)
- 15 V
+15V
Gnd (+5 V)
+ 5 V
+ 15 V
J49 Auxiliary Power
Power
100-240 VAC
50-60 Hz, 1-2 A
DA Output
J24
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
LAN 2
LAN 1
DEBUG
MOT
O
ROLA
10/100 BASE T 10/100 BASE T
SCSI
BUSY
PIB
BUSY
PCI MEZZANINE CARD
PCI MEZZANINE CARD
J55 Dig Out
Dig In J54
J43A
J43B
J49
Aux Pwr
Estop/Run J23
Interlock
J29A
J29B
Load Frame
J28 HSM
A-B
HPU J25