Model 494.42 single-station system board, About the model 494.42 single-station system board, Model 494.42 single-station system board 67 – MTS FlexTest Models 200 User Manual
Page 67: Board features

Model 494.42 Single-Station System Board
MTS FlexTest® Models 40/60/100/200 Controller Hardware
FlexTest Controller Configurations
67
Model 494.42 Single-Station System Board
About the Model 494.42 Single-Station System Board
The Model 494.42 System Board is a two-
slot board that is only used in the Model
494.04 Chassis. This board provides analog
and digital I/O, E-Stop, HSM, UPS, and
HPU control for one station.
Board features
External Interfaces
•
Three digital inputs (J54)
•
Three digital outputs (J55)
•
Auxiliary power outputs for external
devices (J49)
•
UPS inputs (J56) ACFail and low
battery inputs (switch contacts)
•
Two analog outputs (DA Output
connector on the 494.04 chassis)
Hydraulic Control
•
24-volt HPU control (J25)
•
24-volt HSM control (Off/Low/High or
proportional) for one HSM (J28)
E-Stop/Interlock Control
•
Load-frame E-Stop and crosshead
control for one load frame (J29)
•
Optional E-Stop inputs (J24-located on
the 494.04 chassis)
•
Interlock (J43) provides one interlock
input, one interlock output, and a
software-defined event input
•
E-Stop/Run outputs (J23)
Power
100-240 VAC
50-60 Hz, 1-2 A
DA Output
J24
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
LAN 2
LAN 1
DEBUG
MOT
O
ROLA
10/100 BASE T 10/100 BASE T
SCSI
BUSY
PIB
BUSY
PCI MEZZANINE CARD
PCI MEZZANINE CARD
J54
Dig In
J55 Dig Out
J43 INTLK
J56 UPS
J49
Aux Pwr
J23 Estop/Run
J29 Load Frame
J25 HPU
J28 HSM
J54 Dig In
J55 Dig Out
J43 INTLK
J56 UPS
J49 Aux Pwr J23 Estop/Run
J29 Load Frame J25 HPU
J28 HSM
J49 AUX PWR
Auxiliary DC supply
voltages for external
devices:
+ 5 V DC, +15 V DC,
-15 V DC, +24 V DC
J28 HSM
24-volt control for
HSM off/low/high or
proportional solenoid
plus an HSM Estop
input
J43 Intlk
Interlock input
Interlock output
Event input
J29 Load Frame
Load Frame E-Stop
J25 HPU
24 V DC HPU control
for one HPU channel
J54 Dig In
Digital inputs (3)
J55 Dig Out
Digital outputs (3)
Model
494.04
Chassis
J23 Estop/Run
2 Estop NO outputs
1 set of Run NO/NC
outputs
DA Output (2))
J24 E-Stop
(Optional)
J56 UPS
UPS digital inputs
ACFail, Low battery