Transition boards, About transition boards, Transition boards 237 – MTS FlexTest Models 200 User Manual
Page 237: About transition boards 237

Transition Boards
MTS FlexTest® Models 40/60/100/200 Controller Hardware
Digital I/O and Transition Boards
237
Transition Boards
About Transition Boards
Transition boards plug into the transition card cage located in the rear of the
chassis. Each transition board allows external devices to interface with the
controller.
Note
The Model 494.04 Chassis does not use transition boards.
Series 494 Transition Boards
T
RANSITION
B
OARD
F
UNCTION
Model 493.72 Digital I/O
Contains sixteen general purpose digital input channels and sixteen
general purpose digital output channels.
Model 493.73 HPU Interface
Provides an interface between the controller and a hydraulic power unit
(HPU) and other devices.
Model 494.74 Two-Station HSM
Interface
Provides an interface between the controller and a hydraulic service
manifold and other devices. This is a one-slot board that provides off/
low/high HSM control for up to two stations.
Model 493.74 Two-Station HSM
Interface
Interfaces the controller with a hydraulic service manifold and other
devices. This is a two-slot board that provides off/low/high and
proportional HSM control for up to two stations.
Model 494.75 8-Input BNC
Provides eight BNC connections for analog input signals and RJ-50
connectors that route these signals to the Model 494.45 A/D Converter
mezzanine card.
Model 494.76 8-Output BNC
Provides eight BNC connections for analog output signals. RJ-50
connectors route these signals from the Model 494.46 D/A Converter
mezzanine card to the BNC board.
Model 494.79 8-Channel Valve
Driver
Contains eight separate valve drivers. Each valve driver requires an
external valve-drive signal, provided by a Model 494.46 8-Output D/A
mezzanine card.