MTS FlexTest Models 200 User Manual
Page 191

Model 494.47 Dual UART/Encoder Interface Card
MTS FlexTest® Models 40/60/100/200 Controller Hardware
Mezzanine Cards
191
SSI Encoder (Temposonics R) Connections for the Model 494.47 Card
JXA
+ Clk
- Clk
+ Data
- Data
2
3
5
6
DC Power +
-
Temposonics R
Transducer
I/O Carrier Board
Front-Panel
RJ-50 Connectors
JXA and JXB
JXB
Mezzanine
Card
494.47
Dual UART/
Encoder
Conditioner
+ Clk
- Clk
+ Data
- Data
2
3
5
6
DC Power +
-
Temposonics R
Transducer
Cable Grounding
1 The cable shield connects
to the metal shielding on
the RJ-50 cable plug.
2 The cable plug shielding
connects to the I/O carrier
board body.
3 The I/O carrier board
connects to earth ground
through the chassis.
4 The negative (-) side of
the DC Power must be
connected to signal
ground on the controller
chassis.