Specifying print format parameters
4-8
Using LCDS Print Description Language
Options
Default
NOWAIT
ABNORMAL
OTEXT parameter
example
Following is an example of the ABNORMAL OTEXT parameter.
ABNORMAL REP
Specifies whether or not the first data page delivered to the
output bin following a printer jam recovery or a system rollover is
offset from the rest of the report.
Syntax
ABNORMAL REP = {NO | YES}
Options
Default
NO
Table 4-8. ABNORMAL OTEXT parameter options and definitions
Option
Definition
WAIT
Displays a message and stops printing until the operator resumes it (by
pressing the printer Continue button or selecting Resume from the print
server screen). Stopping printing allows the operator to verify the output
report in the near vicinity of the marker page.
NOWAIT
Displays a message, but printing does not stop.
ABNORMAL
OTEXT = WAIT, ERROR = ABORT;
Table 4-9. ABNORMAL REP parameter options and definitions
Option
Definition
NO
Specifies that the page will not be offset.
YES
Specifies that the page will be offset.