beautypg.com

Xerox 4112-4127 Enterprise Printing System-192 User Manual

Page 147

background image

Specifying input parameters

Using LCDS Print Description Language

2-39

The tape label contents can override a record length value. If
a defined record length is larger than the default block length
(1330), you must specify a block length that is large enough
to hold the record. If a large enough record length is not
specified, data may be lost.

The RECORD LENGTH parameter may be overridden by
ANSI or IBM OS/Standard labels that specify record length.

The length on a 4-by-3 packed format tape is the number of
6-bit characters in the record.

RECORD LMULT

Specifies a multiplication factor that is applied to the contents of
the record length field to determine the true record length.

Syntax

RECORD LMULT = value

Options

Default

1

RECORD LTHFLD

Specifies the length of the field that contains the record length.

Syntax

RECORD LTHFLD = size

Options

Default

0

Table 2-42. RECORD LMULT parameter options and definitions

Option

Definition

value

An integer in the range of 1 to 15 that is multiplied by the value in the length
field (refer to the RECORD LENGTH parameter section in this chapter) to
compute the number of bytes in the record.

Table 2-43. RECORD LTHFLD parameter options and definitions

Option

Definition

size

An integer from 0 to 5 that specifies in bytes the length of the field that contains
the record length.