Monitoring sdsl cell alarms, Sdsl c, Onitoring – ADC AVIDIA SWD4573I1 User Manual
Page 577: Larms

Chapter 28: Monitoring System Alarms and Status
Avidia System Configuration and Management User Manual
551
The
SDSL Alarm History
window displays the following information for the selected port,
including both alarm history (since the card was last reset) and alarm status for the current
15-minute data collection interval. The current alarm status displays for both the
Network
(upstream) and
Customer
(downstream) traffic.
M
ONITORING
SDSL C
ELL
A
LARMS
You can monitor current SDSL cell alarm status.
1
Do one of the following:
•
In the
Site Map Navigation
window, click
SDSL Cell Alarm
.
•
In the
Tree Navigation
window, click
Alarm
,
SDSL Cell Alarm Status
.
The
SDSL Cell Alarm
window displays.
Information Description
Card Description
Slot
Port
The description, slot and port of the card for which
the alarm information is displayed.
Margin Threshold Exceeded
The number of seconds the actual margin exceeded
the configured threshold.
Errored Seconds
The number of seconds during which errors
occurred that prevented the payload from being
corrected.
Unavailable Seconds
The number of seconds during which the line was
unavailable. A line becomes unavailable at ten
consecutive severely errored seconds.
Loss of Sync Word
The number of seconds during which one of the
SDSL loops was out of sync.