Monitoring System Alarms

548

Avidia System Configuration and Management User Manual

Most Serious Alarm

The most serious alarm that is occurring in the corresponding slot. The
currently supported alarms are:

Chassis Alarms

critical

Chassis power alarm

One or more chassis power inputs is down.

Chassis fan failure

One or more of the four chassis fans is down.

Chassis temperature alarm

The chassis temperature has exceeded

the allowable threshold. This threshold is not user configurable.

Chassis line card down alarm

The management card cannot

communicate with the line card.

Chassis cell bus down alarm

The cell bus is not operational.

ADSL Alarms

minor

ADSL Loss of Frame (ATU-C/ATU-R)

The Loss of Framing 15 minute

interval threshold has been exceeded.

ADSL Loss of Signal (ATU-C/ATU-R)

The Loss of Signal 15 minute

interval threshold has been exceeded.

ADSL Errored Seconds (ATU-C/ATU-R)

The Errored Seconds 15

minute interval threshold has been exceeded.

ADSL RLPRs (Loss of Power) (ATU-C/ATU-R)

Either the ATU-C or

ATU-R has lost power.

ADSL Rate Change (ATU-C/ATU-R)

The actual rate is different than

the configured rate.

ADSL Initialization Failure Trap (ATU-C/ATU-R)

ADSL line

initialization failed.

Alarm Severity

The severity of the most serious alarm that is occurring.

Information Description