ADC AVIDIA SWD4573I1 User Manual
Page 535

Chapter 25: Monitoring
Subscriber
Connections
Avidia System Configuration and Management User Manual
509
Current State (Upstream/Downstream)
The current status of the ADSL loop. Options:
•
noDefect
—
There are no errors on the line.
•
lossOfLink—The ATU-C was unable to link with the
ATU-R.
•
lossOfFraming
—
The line is not receiving valid
frames.
•
lossOfSignal
—
The line is not receiving valid
signal.
•
lossOfPower
—
The line is not receiving power.
•
lossOfSignalQuality
—
The margin has fallen
below the configured target margin or the BER
exceeds 10
-7
.
•
dataInitFailure
—
The ATU was unable to initialize.
•
configInitFailure
—
The ATU was unable to
initialize because the ATU at the other end does not
support the requested configuration.
•
protocolInitFailure
—
The ATU was unable to
initialize because of an incompatible protocol used
by the peer at the other end.
•
noPeerAtuPresent
—
The ATU was unable to
initialize because no activation sequence was
detected from the ATU at the other end.
Vendor ID (ATU-R/ATU-C)
The vendor ID of the ATU-C and the ATU-R. not
allocated means there is no ATU-R present in the
circuit.
Version Number (ATU-R/ATU-C)
The version number of the ATU-C and the ATU-R.
Status Box
Description