beautypg.com

ADC AVIDIA SWD4573I1 User Manual

Page 158

background image

Configuring IDSL Alarm Profiles

132

Avidia System Configuration and Management User Manual

Examples

::alarm=> show 1

::alarm=> show

The following screen shows an example of both show alarm commands.

Information

Description

Index

The index number of the alarm profile

.

Hourly ES

The number of errored seconds that must be met or
exceeded on the IDSL line within an hour for a trap to
occur. The range is 0 (disable) to 255.

Hourly SES

The number of severely errored seconds that must be
met or exceeded on the IDSL line within an hour for a
trap to occur. The range is 0 (disable) to 127.

Daily ES

The daily ES threshold is the number of errored
seconds that must be met or exceeded on the IDSL
line within a day for a trap to occur. The range is 0
(disable) to 4095.

Daily SES

The number of severely errored seconds that must be
met or exceeded on the IDSL line within a day for a trap
to occur. The range is 0 (disable) to 2047.

::alarm=> show 1

Hourly

Hourly

Daily

Daily

Index

ES

SES

ES

SES

1

40

10

100

25

::alarm=> show

Hourly

Hourly

Daily

Daily

Index

ES

SES

ES

SES

1

40

10

100

25

2

40

15

100

30

3

50

10

125

25