ADC AVIDIA SWD4573I1 User Manual
Page 323

Chapter 13: Monitoring
Network
Connections
Avidia System Configuration and Management User Manual
297
A screen similar to the following displays.
The following information displays:
•
The frame card slot number and port number in the format slot.port (for example, port 5.1).
•
The total number of frames transmitted.
•
The total number of frames received.
•
The total number of characters transmitted.
•
The total number of characters received.
•
The total number of frames received with FECN.
•
The total number of frames received with BECN.
•
The total number of invalid frames received.
•
The total number of short (less than 5 octets) frames received.
•
The total number of long (more than 8193 octets) frames received.
•
The total number of frames received with invalid an DLCI.
•
The total number of frames received with unknown DLCI.
•
The total number of frames received with unknown error.
•
The total number of received frames aborted.
::link=> show 5.1
Link statistics for Frame Relay port 5.1:
Total number of frames transmitted
538875
Total number of frames received
565157
Total number of characters transmitted
33348121
Total number of characters received
34494696
Total number of frames received with FECN
0
Total number of frames received with BECN
0
Total number of invalid frames received
71
Total number of short(< 5 octets) frames rcvd
0
Total number of long(> 8193 octets) frames rcvd
0
Total number of frames received with invalid DLCI 0
Total number of frames received with unknown DLCI 71
Total number of frames rcvd with unknown error
0
Total number of received frames aborted
0
Total number of sent frames aborted
0
Type of error last seen on this interface
unknownAddress(5)
Number of times link went down since initialized
0