Chapter 20: Configuring Subscriber Services

Avidia System Configuration and Management User Manual

389

The

ADSL Alarm Profile Table

window displays the configured ADSL alarm profiles. Click

and

if necessary to view the entire table.

displays the beginning of the table.

displays the next page of the table.

Adding ADSL Alarm Profiles

You add ADSL Alarm profiles from the

ADSL Alarm Profile Table

window.

1

In the

Upstream

and

Downstream

15 Minutes Threshold Loss of Frame

boxes, type a value for

this threshold, or type

0

to disable the trap.

The loss of frame threshold determines the acceptable number of seconds in a 15-minute
ADSL performance data collection period during which the frames lose sync on the ADSL
interface. In a normal environment with sufficient margin, a typical loss of frame threshold
value is 10.

2

In the

Upstream

and

Downstream

15 Minutes Threshold Loss of Signal

boxes, type a value for

this threshold, or type

0

to disable this trap.

The loss of signal threshold determines the acceptable number of seconds in a 15-minute
ADSL performance data collection period during which the line power falls below the
target margin threshold. In a normal environment with sufficient margin, a typical loss of
signal threshold value is 10.