Chapter 26: Monitoring

Network

Connections

Avidia System Configuration and Management User Manual

523

The

Path Current Performance

window provides the following information:

Information

Description

Slot
Card Description

The slot number and description of the line card for which the
Path current performance is displayed.

Port

The port number for which the Path current performance is
displayed.

Width

The designated optical bandwidth.

Status

The status of the interface. Options:

sonetPathNoDefect

There are no errors on the Path layer.

sonetPathSTSLOP

There is a Loss of Pointer error on the

interface.

sonetPathSTSAIS (Alarm Indication Signal)

There is an

alarm at the local end of the SONET line.

sonetPathSTSRDI (Remote Defect Indication)

There is an

alarm at the remote end of the SONET line.

sonetPathUnequipped—The Path layer is not configured
properly at the remote end.

sonetPathSignalLabelMismatch—The Path layer is not
properly provisioned.

Errored Seconds

The number of seconds during which at least one Path layer
bipolar error was detected or an Alarm Indication Signal - Path
(AIS-P) error was present.

Severely Errored Seconds

The number of seconds during which 2,500 or more Path layer
bipolar errors were detected or an AIS-P or Loss of Pointer -
Path (LOP-P) error was present.

Coding Violations

The number of bipolar errors detected at the Path layer.

Unavailable Seconds

The number of seconds during which the Path was unavailable.
A Path becomes unavailable after ten consecutive severely
errored seconds.

Far End Errored Seconds

The count of seconds during which at least one Path layer
bipolar error was reported by the far-end or a one-bit RDI-P
(Remote Defect Indicator - Path) error was present.

Far End Severely Errored
Seconds

The number of seconds during which 2,500 or more Path
bipolar errors were reported by the far-end or a one-bit RDI-P
error was present.

Far End Coding Violations

The number of bipolar errors reported by the far-end and
reported back to the near-end using the RDI-P indication.

Far End Unavailable Seconds

The number of seconds during which the Path was unavailable
at the far end.