Deleting idsl alarm profiles – ADC AVIDIA SWD4573I1 User Manual
Page 436

Configuring IDSL Alarm Profiles
410
Avidia System Configuration and Management User Manual
4
In the
Daily SES
box, type the desired severely errored second threshold in seconds, or type
0
to disable this trap. The range is 0 to 2047, with 25 as the default.
The Daily SES Threshold is the number of severely errored seconds that must be met or
exceeded on the IDSL line within a day for an alarm to display. A severely errored second
generates when the number of block errors (CRC violations) defined by the SES threshold
parameter (see
“Adding ADSL Line Profiles” on page 387
) are detected during a one
second interval.
5
Click
Add
to add the IDSL alarm profile.
Deleting IDSL Alarm Profiles
1
In the
IDSL Alarm Configuration Profile Table
window, locate the table row that contains the
IDSL alarm configuration profile you want to delete.
Click
and
if necessary to view the entire table.
displays the beginning of the
table.
displays the next page of the table.
2
Select the
Delete
check box next to the row that contains the profile you want to delete. To
select the
Delete
check box for all rows (except the default profile, which cannot be
deleted), click
Check All
.
If you decide not to delete a selected row, clear the
Delete
check box next to the row. Click
Clear All
to clear the
Delete
check box for all rows.
3
Click
Delete Checked Row(s)
to delete the profiles.
A confirmation dialog displays.
4
Do one of the following:
•
Click
OK
to delete the selected table rows.
•
Click
Cancel
to not delete the table rows.
You cannot delete profiles that are assigned to ports.