beautypg.com

Configuring and initiating oam loopbacks, Setting the system oam source location id, Configuring and initiating oam loopbacks” on – ADC AVIDIA SWD4573I1 User Manual

Page 368: Oam l, Onfiguring, Nitiating, Oopbacks

background image

Configuring and Initiating OAM Loopbacks

342

Avidia System Configuration and Management User Manual

C

ONFIGURING

AND

I

NITIATING

OAM L

OOPBACKS

OAM loopbacks enable the testing of PVCs by sending cells from one connection point of a
PVC to another, where they are looped back to the originating point. Before beginning any
OAM loopbacks, ensure that the OAM Source Location ID is set for the Avidia system as
described in the following paragraph.

Setting the System OAM Source Location ID

It is important to set the OAM Source Location ID for the Avidia system, as it enables the
system to determine whether or not it is the originator of received loopback cells. The Source
Location ID default is ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff:ff. Set a unique Location ID prior to
initiating a loopback, as other devices involved in the loopback could default to the same
Location ID. It is recommended that the OAM Source Location ID address for the Avidia
system is set up with:

a unique address that is meaningful to you for the first 13 octets

all zeros for the last three octets

Configure the OAM Source Location ID from the

::oam=>

prompt.

1

From the ::root=> prompt, type the following command then press

to display the

::oam=>

prompt.

configuration atm oam

2

Type the setlocation command in the following format, where x is an integer 0 - 9 or an
alpha character a - f, then press

.

setlocation

:xx>

Example

::oam=> setlocation a1:c3:c2:f5:00:bb:23:c7:92:d5:e3:23:

9a:11:ff:73

ENTER

ENTER