Adding spvcs – ADC AVIDIA SWD4573I1 User Manual
Page 482

Configuring SPVCs
456
Avidia System Configuration and Management User Manual
Adding SPVCs
1
In the
SPVC Configuration
window, click
.
The
Add SPVC Configuration
window displays.
2
In the
Admin Status
box, select
Up
to activate the SPVC or select
Down
to deactivate it.
3
In the
Channel Slot
and
Port
boxes, select the channel card slot and port.
4
In the
Channel VPI
and
VCI
boxes, type the VPI and VCI of the PVCC between the CPE and
the line card.
5
If the PVCC uses a frame channel card, in the
Channel Encap
box select the Encapsulation
mode (options:
LLC_8023
or
VC_MUX_8023
).
6
In the
Destination ATM Address
box, type the ATM address of the destination ATM end
system.
The address can be up to 20 octets. The first octet must be 39, 45, or 47. Each octet must
be separated by a colon.
7
In the
Destination Retry Interval
box, type a retry interval value between 0 and 3600.
The retry interval is the number of seconds the system waits before reattempting to
establish the SPVC after a failed call attempt.