Chapter 26: Monitoring

Network

Connections

Avidia System Configuration and Management User Manual

521

Line Current Performance

Port

The port number for which the Line current performance is
displayed (each line card has two ports).

Status

Options:

sonetLineNoDefect

There are no errors on the SONET

line.

sonetLineAIS (Alarm Indication Signal)

There is an alarm

at the local end of the SONET line.

SonetLineRDI (Remote Defect Indication)

There is an

alarm at the remote end of the SONET line.

Errored Seconds

The number of seconds in the current 15 minute performance
monitoring interval during which at least one Line layer bipolar
error was detected or an Alarm Indication Signal - Line (AIS-L)
error was present.

Severely Errored Seconds

The number of seconds in the current 15 minute performance
monitoring interval during which 2,500 or more Line layer
bipolar errors were detected or an AIS-L error was present.

Coding Violation

The number of bipolar errors detected at the Line layer.

Unavailable Seconds

The number of seconds during which the line was unavailable.
A line becomes unavailable at ten consecutive severely errored
seconds.

Far End Errored Seconds

The number of seconds during which at least one Line layer
bipolar error was reported by the far-end or a Remote Defect
Indicator - Line (RDI-L) error was present.

Far End Severely Errored
Seconds

The number of seconds during which 2,500 or more Line layer
bipolar errors were reported by the far end or an RDI-L error
was present.

Far End Code Violations

The number of bipolar errors detected by the far end and
reported back to the near end.

Far End Unavailable Seconds The number of seconds during which the line is unavailable at

the far end.

Information

Description